FUJI错误代码查询 - 第618页
also occur if the cleaner notch is out even though the cleaner was not at the escape position. Remedy: In the former instance, use [HEAD ATTACHMENT] on command page 553-2(4) to properly connect the cleaner to the drive a…
Cause: System error.
Remedy: Cut the power and reboot the machine. If the problem recurs, contact Fuji.
------------------------------
Code: 12063024
Display:
Used by:
Cause: Even though the head was not over the screen, an attempt was made to execute the solder
discharge command.
Remedy: Inch the head over the metal portion of the screen and execute the solder discharge command.
------------------------------
Code: 12063025
Display: Interlock Z
Used by: GSP5
Cause: The camera station may collide with the main table.
Remedy: Inch the Z-axis close to its zero set position (the position at which the Z-axis origin sensor,
Z_AXIS_ZERO, turns on).
------------------------------
Code: 12063026
Display: XL XR Interlock
Used by:
Cause: The L camera and R camera proximity sensor was activated
Remedy: Separate the L and R cameras either manually or by inching.
------------------------------
Code: 12063027
Display: Obstruction In Screen Path
Used by:
Cause: Stencil transport was not possible because of an obstruction in the stencil transport path.
Remedy: Remove the obstruction.
------------------------------
Code: 12063028
Display: 请拆下网板
[Please Screen Release]
Used by: GP551,GP6,GPX,NXTP
Cause: 现在,网板正处于夹紧中。在更换支架时有网板的情况下发生。 存在网板框 (GPX)
Remedy: 请松开网板(指令页 558(2)「松开」),然后拆下。 请将网板框取出。(GPX)
<img src="$LKEY_ERRIMG_MC$/12063028.PNG">
------------------------------
Code: 12063029
Display: "Please Cleaner escape"
Used by: GP551,GP6
Cause: This error occurs if the holder is changed while the cleaner is not at the origin position.
Remedy: Move the cleaner to the origin position (the position at which X05C:CLNR ZERO POS" shows a
value of 0). If necessary, make sure that the lower cleaner origin position check sensor (X05C:CLNRZERO
POS) is functioning normally.
------------------------------
Code: 1206302A
Display: "Cleaner Did Not Connect"
Used by: GP551,GP6
Cause: This error may occur if an attempt is made to close the cleaner head while the connection status
between the cleaner and the cleaner drive axis is inappropriate: either the cleaner notch that connects the
cleaner to the drive axis was not inserted, or the cleaner is not proximate to the drive axis. This error may
第 617 页
also occur if the cleaner notch is out even though the cleaner was not at the escape position.
Remedy: In the former instance, use [HEAD ATTACHMENT] on command page 553-2(4) to properly
connect the cleaner to the drive axis. If necessary, make sure that the lower cleaner connection check
sensor and the cleaner connection position proximity check sensor (X05D:LW CLR CPL CHK and
X03E:CLNR NEAR CHK) are functioning normally. In the latter case, manually return the cleaner to the
origin position.
------------------------------
Code: 1206302B
Display: "Cleaner Sandwich Position Out of Range"
Used by: GP6
Cause: This error occurs if an attempt is made to close the cleaner head while the cleaner is at an
inappropriate position. The cleaner is either at the origin or outside the cleaning range.
Remedy: Move the cleaner inside the cleaning range. On a double-side cleaner, the cleaning range is
between the positions set by the following Proper data parameters: "222:Max Limit Position S clnr"and
"223:Min Limit Position S clnr." On a single-side cleaner, it is between the positions set by the following
Proper data parameters: "232:Max Limit Position Y clnr" and "233:Min Limit PositionY clnr."
------------------------------
Code: 1206302C
Display: "Cleaner Notch Action Error"
Used by: GP6
Cause: Removal of the cleaner notch required longer than the specified time. This error may also occur if
the cleaner notch is in even though the cleaner is not proximate to the cleaner drive axis (the Y-axis for a
double-side cleaner, or the S-axis for a single-side cleaner).
Remedy: Use I/O commands to check the sensor. If necessary, return the cleaner to the proper status.
------------------------------
Code: 1206302D
Display: "Cleaner XY catch"
Used by: GP6
Cause: Removal of the notch connecting the single-side cleaner to the XY-axis required longer than the
specified time.
Remedy: Use I/O commands to check the sensor.
------------------------------
Code: 1206302E
Display: "Move SQG Start Position at Printing"
Used by: GP551,GP6
Cause: This error occurs if automatic operation is started with the double squeegee positioned inside the
printing area.
Remedy: Move the squeegee outside the printing area, either to the front or rear side.
------------------------------
Code: 1206302F
Display: 请除去印刷状态不明的电路板
[Printing Not Possible. Remove Board]
Used by: GPX,NXTP
Cause: 判断出主搬运轨道的电路板正处在印刷途中。印刷途中的电路板不能够印刷。
Remedy: 请除去主搬运轨道的电路板,修正后,从IN搬运轨道处载入。
<img src="$LKEY_ERRIMG_MC$/1206302F.PNG">
------------------------------
Code: 12063030
Display: "Univ holder at inner limit"
Used by: GP551,GP6
Cause: Board holder interference occurred while changing the conveyor width. This error occurs when
第 618 页
the board holder has not been detached, or when the board holder size is inappropriate.
Remedy: Detach the board holder.
------------------------------
Code: 12063031
Display: 侧夹紧错误
Used by: GPX,NXTP
Cause: 侧夹紧落空
Remedy: 请从主搬运轨道处除去落空的电路板。
<img src="$LKEY_ERRIMG_MC$/12063031.PNG">
------------------------------
Code: 12063032
Display: 电路板厚度异常
Used by: GPX,NXTP
Cause: 检测到边缘夹紧顶起。电路板厚度可能有异常。
Remedy: 1.请确认电路板厚度。
2.请查看用于确认电路板厚度的传感器(※1)。(请联系售后服务人员)
※1 NXTP:RX008、RX009
GPX :RX000
<img src="$LKEY_ERRIMG_MC$/12063032.PNG">
------------------------------
Code: 12063033
Display: 定位点尺寸测量错误 电路板
Used by: GPX,NXTP
Cause: 电路板的定位点尺寸测量失败。
Remedy: 1.请确认定位点是否脏。
2.请确认定位点形状及检索范围是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12063033.PNG">
------------------------------
Code: 12063034
Display: 定位点尺寸测量错误 钢板
Used by: GPX,NXTP
Cause: 钢板的定位点尺寸测量失败。
Remedy: 1.请确认定位点是否脏。
2.请确认定位点形状及检索范围是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12063034.PNG">
------------------------------
Code: 12063035
Display: 补正计算异常
基准定位点同一位置
Used by: GPX,NXTP
Cause: 基准定位点的位置被指定成了同一位置。
同一位置时,不能够进行角度补正。
Remedy: 定位点的位置请尽量指定有一定距离的不同的2点。
<img src="$LKEY_ERRIMG_MC$/12063035.PNG">
------------------------------
Code: 12063036
Display: 电路板落下了
Used by: GPX
Cause: 通过相机机械手检查了主搬运轨道的电路板有无,但是电路板到达传感器却无法测出。
Remedy: 可考虑在双印刷的夹紧中电路板落下了。请确认是否有落下的电路板。有可考虑在没有放入电路板的情况下
按下了启动SW的情况。
第 619 页