FUJI错误代码查询 - 第651页
------------------------------ Code: 120661?? Display: Bad nozzle detected:PM??-? Used by: QP132 Cause: The number of vision processing errors has exceeded the specified figure, and the nozzle is therefore judged to be d…
Display: Auto Tape Supply Err
Used by: GL541
Cause: The tape was not fed from the automatic tape supply unit.
Remedy: Make sure that the tape has not been cut and that the automatic tape supply unit has not been
removed.
------------------------------
Code: 12066000
Display: SS-axis Interlock
Used by:
Cause: (1) There is a possibility that the position where the step slide axis is currently located might
interfere with a pallet loading or unloading. (2)The combination of the step slide pin and the step slide
axis being unclamped prohibits inching. (3) The process is prohibited because the step slide pin is
engaged.
Remedy: (1), (3) When automatic operation is restarted following the clearing of an emergency stop
during index motion, there is a possibility that the step slide might interfere with a pallet loading or
unloading.
It is because of this that the SS-axis must be moved to a safe position. If at this time, the step slide is
clamped to the pallet, the SS-axis and the entire pallet are moved together. Be careful that the pallet
position is not out of place because, if it is, operation cannot be restarted. Generally though, unclamp the
pallet and move just the SS-axis.
1. If the pallet is clamped, set Y04F: SS_PLT_UNCLAMP1 and Y061: SS_PLT_UNCLAMP2 to ON and
unclamp the pallet.
2. Set Y063: SS_PIN_OFF to ON and disengage the SS-axis pin.
3. Check that the X06B: SS_PIN_OFF setting and the X066: SS_PLT_UNCLAMP setting is ON.
------------------------------
Code: 12066001
Display:
Used by: QP132
Cause: The machine stopped due to a pallet initiation error which occurred during the first half of
processing.
Remedy: Execute PLT CHANGE and try initiation again. When changing pallets, remove only the pallet
located in the front. It is possible to re-execute initiation without removing the pallet located in the rear
(the return conveyor side).
------------------------------
Code: 12066002
Display:
Used by: QP132
Cause: The machine stopped due to a pallet initiation error which occurred during the second half of
processing.
Remedy: Perform PLT CHANGE and try initiation again. When changing pallets, remove only the pallet
located in the front. It is possible to re-execute initiation without removing the pallet located in the rear
(the return conveyor side).
------------------------------
Code: 12066003
Display: Vision Time out
Used by: QP132
Cause: Vision processing was not completed within the set time. The time out duration depends on the
content of vision processing.
Remedy: If the error LED of the vision processing board VP4100/4800 is on, the board may be defective.
If the same error occurs when operation is resumed, restart the machine. If the placing head is holding
parts, first dump the parts and then restart the machine.
第 650 页
------------------------------
Code: 120661??
Display: Bad nozzle detected:PM??-?
Used by: QP132
Cause: The number of vision processing errors has exceeded the specified figure, and the nozzle is
therefore judged to be defective.
The question marks in the code represent the module number and the nozzle number in that order. The
first two question marks in the display represent the module number, and the question mark after the
hyphen represents the nozzle number.
Remedy: Check the status of the nozzles.
------------------------------
Code: 12066800
Display: DATA LOGIC ERROR [12066800]
Used by: QP132
Cause: There is no data table for setting the fiducial mark that has been read. Or The Pallet ID issued
during advanced pick-up is incorrect. On the QP132, the board information is saved in the table when the
board is loaded, and Data is written to each pallet ID at the Approach Station. As a result, when a board
exists in the pallet loader after being set using the I/O operation, the board information will be deleted if
the reset-start operation is carried out thereby making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066801
Display: DATA LOGIC ERROR [12066801]
Used by: QP132
Cause: There is no program to be executed at the mark read station.
Remedy: Transmit the necessary program.
------------------------------
Code: 12066802
Display: DATA LOGIC ERROR [12066802]
Used by: QP132
Cause: When the pallet size corresponding to the stored ID was read, data different than the pallet size
being used in production was detected.
Remedy: Check the pallet size in the machine. Has the wrong size pallet been inserted? If a pallet change
has been carried out the pallet initialization operation may not in fact be necessary, nevertheless this
initialization operation should always be carried out when a new pallet is used. Also note that the
possibility exists that the pallet initialization operation is not properly completedevery time. In such a case
execute the [PLT CHANGE] command, unload the pallets, and then execute the [INITI TION] command.
------------------------------
Code: 12066803
Display: DATA LOGIC ERROR [12066803]
Used by: QP132
Cause: The pitch was not continuous when the five individual IDs attached to the pallet were read at the
approach station.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
第 651 页
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066804
Display: DATA LOGIC ERROR [12066804]
Used by: QP132
Cause: A data table for managing the pallet is created at the approach station however, there was no
empty table available and thus this data table could not be created. This is an ID read mistake due to
damage to the pallet ID reader. Or there is a bug in the QP132 software.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066805
Display: DATA LOGIC ERROR [12066805]
Used by: QP132
Cause: The ID number did not conform when the five individual IDs attached to the pallet were read at
the approach station. Or Inconsistences also exist.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command.
Once the SS-axis has been returned to its origin position using the [SS Move] command, ensure that the
error has been cleared. It will not be possible to proceed with operation unless the error is cleared. This
[ID Number] can only be written when the pallets are loaded. When replacing a damaged pallet, remove
the ID plate from the previous pallet and attach it to the new one. In addition, there is also the possibility
that previous pallet loading was not completed successfully on the previous board. In this situation,
perform the [Load Pallet] command once all pallets have been unloaded.
------------------------------
Code: 12066806
Display: DATA LOGIC ERROR [12066806]
Used by: QP132
Cause: There was no stored board information when the ID was written at the approach station. On the
QP132, the board information is saved in the table when the board is loaded, and the pallet ID is saved at
the mark read station after the board is loaded. As a result, when a board exists in the pallet loader after
being set using the I/O operation, the board information will be deleted if the reset-start operation is
carried out thereby making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066807
Display: DATA LOGIC ERROR [12066807]
Used by: QP132
Cause: A contradiction was detected such as the pallet length being exceeded, when the ID write
第 652 页