FUJI错误代码查询 - 第657页
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command, ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is cleared.…
Cause: The pallet ID in the report received from the PMC is different from the previous pallet ID. The
pallet ID managed by the PMC is determined at the pallet stopping position and should not change until
the pallet moves during the next circulation. This error will occur if a PMC report mistake is detected, the
SS-axis is inched or if the pallet position is displaced by any circulation of pallets other than the
circulation associated with automatic operation.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066815
Display: DATA LOGIC ERROR [12066815]
Used by: QP132
Cause: This is a malfunction in the software. The buffer was filled without an inquiry being made by
communications packet processing.
Remedy: Cut the power to the machine and then turn it back on. There are also cases where it is
necessary to carry out the flush out operation.
------------------------------
Code: 12066816
Display: DATA LOGIC ERROR [12066816]
Used by: QP132
Cause: The X035: out-conveyor board arrival check sensor (OUT_ARRV_CHK) failed to work correctly. Or
there is a bug in the QP1 software.
Remedy: Carry out a check of the sensor.
------------------------------
Code: 12066817
Display: Same as code
Used by: QP132
Cause: Discontinue.
Remedy: Discontinue.
------------------------------
Code: 12066818
Display: Same as code
Used by: QP132
Cause: The machine has stopped operating because a processing or data inconsistency has been
detected.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066819
Display: PLT size error [12066819]
Used by: QP132
Cause: Pallet size or pitch information outside specified limits has been detected.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
第 656 页
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206681A
Display: Pallet position error [1206681A]
Used by: QP132
Cause: The position of the pallet which was advanced by the index motion does not match the index
motion count. This occurs when a gap occurs between pallets, when a pallet did not advance during index
motion, when there is interference with another part of the machine, and when the SS-axis motor has
broken down.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206681B
Display: Vision Processing result error
Used by: QP132
Cause: VP has reported that the part inspection is complete, however no value has been set.
Remedy: There may be a problem with the vision system board or software. Change the vision system
board or VP-card, and reset-start the machine. If this problem occurs regularly, output trace data from
the machine and send it to Fuji for analysis.
------------------------------
Code: 1206681C
Display: CARRIER ARRANGE ERROR 1206681C
Used by: QP132
Cause: There is no relevant pallet size in the data carrier arrangement pattern.
Remedy: Check the pallet's data carrier arrangement pattern. If the data carrier is broken, replace it.
------------------------------
Code: 1206681D
Display: Pallet position error [1206681D]
Used by: QP132
Cause: A contradiction in the pallet's position at the approach station, mark read module, and landing
station has been detected (Unable to read an ID is also included). This occurs when a pallet did not
advance during index motion, when a gap occurs between pallets or, due for some reason the ID head
cable is unattached and an error occurs when the cable is attached.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206681E
Display: Pallet position error [1206681E]
Used by: QP132
Cause: A contradictory pallet stopping state using the current index motion type has been detected,
第 657 页
causing this error (almost the same as error 1206681D). This especially occurs when the index motion
type is changed with the retransmission of the program.
Remedy: To avoid parts wastage or double parts placement of a part which is in the machine, the index
motion system cannot be changed. Return to the prior index motion setup or,refer to error 1206681D.
------------------------------
Code: 1206681F
Display: DATA LOGIC ERROR [1206681F]
Used by: QP132
Cause: After restarting automatic operation, a program name which differs from the program name
before the machine stopped, is registered in the pallet ID of the pallet at the in-conveyor.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066820
Display: Family condition error
Used by: QP132
Cause: Wrong family condition.
Remedy: Check the index motion type, board width, rotation format, and nozzle configuration, etc.
------------------------------
Code: 12066901
Display: Out-manipulator interlock error.
Used by: QP132
Cause: The in-manipulator came away from its upper limit (X5A: PCB LD UPCHK) while the axes
(MX/MY/SS) were in motion. Alternatively, the axes (MX/MY/SS) were instructed to move when the in-
manipulator was not at its upper limit.
Remedy: Check the upper limit sensor for the in-manipulator.
------------------------------
Code: 12066902
Display: Out-manipulator interlock error.
Used by: QP132
Cause: The out-manipulator came away from its upper limit (X7A: PCB UL UPCHK) while the axes
(PO/SS) were in motion. Alternatively, the axes (PO/SS) were instructed to move when the out-
manipulator was not at its upper limit.
Remedy: Check the upper limit sensor for the out-manipulator.
------------------------------
Code: 12066903
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066904
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
第 658 页