FUJI错误代码查询 - 第663页

Cause: The die cannot be picked becasue there is no die pick information. Remedy: Remove the die using the die removal command. ------------------------------ Code: 12066B08 Display: RADDS error Machine type: QP3 Used by…

100%1 / 5282
------------------------------
Code: 12066B00
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Measurement error. The acquired deviation is outside the acceptable range.
Remedy: Check for damage to the cylinder head, wiring errors, electro-pneumatic regulator errors, and
pressure measurement unit errors.
------------------------------
Code: 12066B01
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Compensation cannot be calculated due to a precise pressure Proper data error. Precise pressure
calibration may not have been performed.
Remedy: Perform precise pressure calibration for the target holder(s).
------------------------------
Code: 12066B02
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Precise pressure controller load range error. Load instruction cannot be issued.
Remedy: Correct the maximum and minimum load range values in the machine configuration file, and
then calibrate the pressure.
------------------------------
Code: 12066B03
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Incorrect value issued to the pressure controller.
Remedy: Perform precise pressure calibration for the target holder(s).
------------------------------
Code: 12066B04
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: An error occurred at the precise pressure controller.
Remedy: Reboot the machine, and inspect the pressure controller if the problem persists.
------------------------------
Code: 12066B05
Display: Pressure measurement unit error.
Used by: NP-2, QP-3
Cause: An error occurred at the pressure measurement unit.
Remedy: Reboot the machine, and inspect the pressure measurement unit if the problem persists.
------------------------------
Code: 12066B06
Display: RADDS error
Machine type: QP3
Used by:
Cause: The Machine memory condition differs to that of RADDS.
Remedy: Remove the die using the die removal command.
------------------------------
Code: 12066B07
Display: RADDS error
Machine type: QP3
Used by:
第 662 页
Cause: The die cannot be picked becasue there is no die pick information.
Remedy: Remove the die using the die removal command.
------------------------------
Code: 12066B08
Display: RADDS error
Machine type: QP3
Used by:
Cause: Some die may still remain on RADDS.
If production is continued any remaining die will fall from the shuttle or inverter.
Remedy: Remove any remaining die from the shuttle and inverter.
Execute the following commands to delete any die references from the RADDS memory.
[RADDS Commands]
1. Close the COMMAND READY window and select "JobInfo" from the main window.
2. Select "Die in Proc" from the ID_DLG_JOB_INFO dialog box.
3. Select "Flush" from the Die in process dialog box.
------------------------------
Code: 12066B09
Display: Serial communication error
Used by: NP2,QP3
Cause: Serial communication error.
Remedy: Reset the part power supply.
------------------------------
Code: 12066C00
Display: RADDS error
Used by: NP2,QP3
Cause: Communication problem with RADDS.
Remedy: Check the RADDS connection.If the connection is OK, reset the RADDS power supply.
------------------------------
Code: 12066C01
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS error stop.
Remedy: Clear the error status as instructed on the RADDS screen.
------------------------------
Code: 12066C02
Display: RADDS error
Used by: NP2,QP3
Cause: Parts out condition at RADDS.
Remedy: Supply RADDS with the required wafer.
------------------------------
Code: 12066C03
Display: RADDS error
Used by: NP2,QP3
Cause: Wafers are being supplied to RADDS.
Remedy: Supply RADDS with wafers, then close the wafer door.
------------------------------
Code: 12066C04
Display: RADDS error
Used by: NP2,QP3
Cause: Temporary stop status at RADDS.
Remedy: Clear the temporary stop status as instructed on the RADDS screen.
第 663 页
------------------------------
Code: 12066C05
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS not connected.
Remedy: RADDS failed to start. Reset the part power supply.
------------------------------
Code: 12066C06
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS failed to start.
Remedy: Reset the part power supply.
------------------------------
Code: 12066C07
Display: RADDS error
Used by: NP2,QP3
Cause: Wafer supply to RADDS was not completed within the prescribed period. Wafer door remains
open.
Remedy: Supply RADDS with wafers, then close the wafer door.
------------------------------
Code: 12066C08
Display: RADDS error
Used by: NP2,QP3
Cause: Unidentified part at RADDS.
Remedy: Inspect the RADDS front shuttle.
------------------------------
Code: 12066C09
Display: RADDS error
Used by: NP2,QP3
Cause: An error occurred during RADDS resetting.
Remedy: Cut the power to the RADDS and then reboot.
------------------------------
Code: 12066C0A
Display: Eject conveyor error
Used by: NP2,QP3
Cause: Feeder is present in slot specified for the reject parts conveyor.
Remedy: Check to see if a feeder is present in the slot indicated in the parameter slot display. Check to
see if a feeder is specified in the production program.
------------------------------
Code: 12066C0B
Display: Nozzle setting error
Used by: NP2,QP3
Cause: Nozzle catch sensor is ON even a although no nozzle is installed.
Remedy: Ensure if a nozzle is set in the holder.If so, reject the nozzle.
------------------------------
Code: 12066C0C
Display: STU data error
Used by: NP2,QP3
Cause: A non-STU type feeder exists within 9 slots to either side of the STU.(NP2)
A feeder has been set in the STU interference area.(QP3)
Remedy: It is prohibited to set non-STU type feeders within 9 slots at both sides of the STU. The