FUJI错误代码查询 - 第669页
------------------------------ Code: 1206703? Display: Nozzle damage has been detected on head 1. Used by: NP133,NP134,NP153 Cause: The nozzle bend check sensor at head 1, 13ST has detected a nozzle error. The question m…
Display: Next device data error
Used by: QP3
Cause: In the next device loop there is a device that has a different part number.
Remedy: Either set shared device to OFF, or if using the shared device function,revise the next device loop
so that the next device has the same part number.
------------------------------
Code: 12067004
Display: Nozzle ejection error!(NP2,QP3)
Used by: NP132,NP133,NP2,QP3
Cause: Failed to eject the nozzle from the shaft.(NP2,QP3)
Remedy: Remove the nozzle from the shaft and place it in the pocket registered in nozzle
memory.(NP2,QP3)
------------------------------
Code: 12067005
Display: Nozzle attachment error!(NP2,QP3)
Used by: NP132,NP133,NP2,QP3
Cause: Failed to attach the nozzle to the shaft.(NP2,QP3)
Remedy: Check if the nozzle is correctly inserted into the shaft.(NP2,QP3)
------------------------------
Code: 12067008
Display: Part supply unit mismatch error.
Used by: NP2,QP3
Cause: Part supply unit being used is different from that specified in the production program.
Remedy: Select a production program suitable for the part supply unit being used.
------------------------------
Code: 12067009
Display: Nozzle selection error!
Used by: QP3
Cause: Insufficient nozzles of the required type.
Remedy: The same nozzle is required for all of the holders. Insert additional nozzles of the required type
info the nozzle station, or change the sequence order so that the same nozzle is not required
simultaneously.
------------------------------
Code: 12067024
Display: Cannot perform automatic pickup point offset
Used by: NP133,NP134,NP153
Cause: The pickup point falls outside the software limit if automatic offsetting is performed. It is likely
that the part is incorrectly positioned.
Remedy: Check the condition of the feeder. Clear the automatic pickup point offset when rebooting.
------------------------------
Code: 12067025
Display: Failed to reset servo amp.
Used by: NP133,NP134,NP153
Cause: Failed to clear servo amp error.
Remedy: Press the RESET button again.
------------------------------
Code: 12067026
Display: motor fan error.
Used by: NP133,NP134,NP153
Cause: Fan motor is damaged.
Remedy: Cut the power and replace the motor.
第 668 页
------------------------------
Code: 1206703?
Display: Nozzle damage has been detected on head 1.
Used by: NP133,NP134,NP153
Cause: The nozzle bend check sensor at head 1, 13ST has detected a nozzle error. The question mark (?)
indicates the nozzle position. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Replace the nozzle, either manually or using the nozzle change command.
------------------------------
Code: 1206704?
Display: Nozzle damage has been detected on head 2.
Used by: NP133,NP134,NP153
Cause: The nozzle bend check sensor at head 2, 13ST has detected a nozzle error. The question mark (?)
indicates the nozzle position. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Replace the nozzle, either manually or using the nozzle change command.
------------------------------
Code: 12067050
Display: Oil cooler error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: An oil temperature error was detected by the oil cooler.
Remedy: Check the oil level in the oil cooler. If this error occurs even though the oil level is as prescribed,
there may be an oil cooler failure.
------------------------------
Code: 12067051
Display: Cam-axis motor fan error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The cooling fan for the cam-axis motor is not operating. Alternatively, it is not running at the
prescribed speed (rpm).
Remedy: If the fan is stopped, there may be a wiring problem or a motor failure. If this error occurs even
though the fan is running, check to see if the fan is soiled. If badly soiled, clean the fan.
------------------------------
Code: 12067052
Display: X-axis motor fan error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The cooling fan for the X-axis motor is not operating. Alternatively, it is not running at the
prescribed speed (rpm).
Remedy: If the fan is stopped, there may be a wiring problem or a motor failure. If this error occurs even
though the fan is running, check to see if the fan is soiled. If badly soiled, clean the fan.
------------------------------
Code: 12067053
Display: D1-axis motor fan error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The cooling fan for the D1-axis motor is not operating. Alternatively, it is not running at the
prescribed speed (rpm).
Remedy: If the fan is stopped, there may be a wiring problem or a motor failure. If this error occurs even
though the fan is running, check to see if the fan is soiled. If badly soiled, clean the fan.
------------------------------
Code: 12067054
Display: D2-axis motor fan error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The cooling fan for the D2-axis motor is not operating. Alternatively, it is not running at the
prescribed speed (rpm).
第 669 页
Remedy: If the fan is stopped, there may be a wiring problem or a motor failure. If this error occurs even
though the fan is running, check to see if the fan is soiled. If badly soiled, clean the fan.
------------------------------
Code: 1206706?
Display: A nozzle error has been detected at head 2, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 2, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 1206707?
Display: A nozzle catch error has been detected at head 1, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 1, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 1206708?
Display: A nozzle catch error has been detected at head 2, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 2, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 12067090
Display: A vacuum pump thermal error has been detected.
Used by: NP133,NP134,NP153
Cause: The vacuum pump power source breaker was switched.
Remedy: Inspect the vacuum pump motor, the 200V main power source, and their connections.
------------------------------
Code: 120670A?
Display: A nozzle error has been detected at head 1, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 1, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 120680??
Display: Parts out error!
Used by: QP3,NP2
Cause:
Remedy: Resupply parts.
------------------------------
Code: 120681??
Display: Parts out error!
Used by: QP3,NP2
Cause:
Remedy: Resupply parts.
------------------------------
第 670 页