FUJI错误代码查询 - 第671页
Code: 120682?? Display: Parts out error! Used by: QP3,NP2 Cause: Remedy: Resupply parts. ------------------------------ Code: 120683?? Display: Parts out error! Used by: QP3,NP2 Cause: Remedy: Resupply parts. -----------…
Remedy: If the fan is stopped, there may be a wiring problem or a motor failure. If this error occurs even
though the fan is running, check to see if the fan is soiled. If badly soiled, clean the fan.
------------------------------
Code: 1206706?
Display: A nozzle error has been detected at head 2, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 2, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 1206707?
Display: A nozzle catch error has been detected at head 1, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 1, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 1206708?
Display: A nozzle catch error has been detected at head 2, 1ST.
Used by: NP133,NP134,NP153
Cause: The nozzle catch check sensor at head 2, 1ST has detected a nozzle catch error. The question
mark (?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. In some cases a nozzle catch error occurs
when the nozzle is stuck.
------------------------------
Code: 12067090
Display: A vacuum pump thermal error has been detected.
Used by: NP133,NP134,NP153
Cause: The vacuum pump power source breaker was switched.
Remedy: Inspect the vacuum pump motor, the 200V main power source, and their connections.
------------------------------
Code: 120670A?
Display: A nozzle error has been detected at head 1, 16ST.
Used by: NP133,NP134,NP153
Cause: The nozzle check sensor at head 1, 16ST has detected a nozzle position error. The question mark
(?) indicates the shaft. If (?) is 0 then the error is on shaft A, if 1 then shaft B, if F then shaft P, etc.
Remedy: Inspect the nozzle and shaft where the error occurred. The nozzle may be stuck.
------------------------------
Code: 120680??
Display: Parts out error!
Used by: QP3,NP2
Cause:
Remedy: Resupply parts.
------------------------------
Code: 120681??
Display: Parts out error!
Used by: QP3,NP2
Cause:
Remedy: Resupply parts.
------------------------------
第 670 页
Code: 120682??
Display: Parts out error!
Used by: QP3,NP2
Cause:
Remedy: Resupply parts.
------------------------------
Code: 120683??
Display: Parts out error!
Used by: QP3,NP2
Cause:
Remedy: Resupply parts.
------------------------------
Code: 12068400
Display: TZ-axis servo amp error.
Used by: QP3,NP2
Cause: Servo amp initialization error. No response from servo amp.
Remedy: Cut and resupply the power to the MTU.
------------------------------
Code: 12068430
Display: TZ-axis: Overtravel error (software limit) in the +direction.
Used by: QP3,NP2
Cause:
Remedy: Check if the correct data has been input for machine calibration data item Max Limit Position
TZ.
------------------------------
Code: 12068431
Display: TZ-axis: Overtravel error (software limit) in the -direction
Used by: QP3,NP2
Cause:
Remedy: Check if the correct data has been input for machine calibration data item Min Limit Position
TZ.
------------------------------
Code: 12068432
Display: TZ-axis: Insufficient servo power.
Used by: QP3,NP2
Cause: A movement command was issued while the power supply to the servos was off.
Remedy: Reset to supply power to the servos.
------------------------------
Code: 12068433
Display: TZ-axis: Positioning time-out error.
Used by: QP3,NP2
Cause:
Remedy: Check the servo parameters and the wiring between the servo amps and the servo motors.
------------------------------
Code: 12068434
Display: TZ-axis: Positioning travel distance limit error.
Used by: QP3,NP2
Cause:
Remedy: Check the axis traveling distances specified in the production program.
------------------------------
Code: 12068435
第 671 页
Display: TZ-axis: File type change error!
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 12068436
Display: TZ-axis: Filter constant change error!
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 12068437
Display: TZ-axis: Origin specification error!
Used by: QP3,NP2
Cause:
Remedy: TZ-axis: Specify the origin.
------------------------------
Code: 12068438
Display: TZ-axis: It is not possible to specify the origin when the axis is moving.
Used by: QP3,NP2
Cause:
Remedy: TZ-axis: Specify the origin after axis movement has been completed or check the range for the
completion of servo amp positioning.
------------------------------
Code: 12068439
Display: TZ-axis: User constant setting error.
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 1206843A
Display: TZ-axis: MECHATROLINK servo synchronization error.
Used by: QP3,NP2
Cause:
Remedy: TZ-axis: Check the wiring between the controller amps and check for servo amp errors.
------------------------------
Code: 1206843B
Display: TZ-axis: MECHATROLINK communication error.
Used by: QP3,NP2
Cause:
Remedy: TZ-axis: Check the wiring between the controller amps and check for servo amp errors.
------------------------------
Code: 1206843C
Display: TZ-axis: MECHATROLINK servo command time-out error.
Used by: QP3,NP2
Cause:
Remedy: TZ-axis: Check the wiring between the controller amps and check for servo amp errors.
------------------------------
Code: 1206843D
Display: TZ-axis: Absolute encoder rotation limit error.
Used by: QP3,NP2
第 672 页