FUJI错误代码查询 - 第687页
Used by: QP3,NP2 Cause: Remedy: Check if the lifer upper limit sensor is on, or if the remover lower limit sensor is off. Also check if there is a delay in lifter ascent. ------------------------------ Code: 12068611 Dis…
Code: 120685AB
Display: TY-axis: Communication error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK communications cable between the MTU controller and servo
amplifier is connected correctly.
------------------------------
Code: 120685AC
Display: TY-axis: Servo response error!
Used by: QP3,NP2
Cause:
Remedy: Replace the servo amplifier.
------------------------------
Code: 120685AD
Display: TY-axis: Servo back initial access error!
Used by: QP3,NP2
Cause:
Remedy: Replace the servo amplifier.
------------------------------
Code: 120685AE
Display: TY-axis: Servo back WDC error!
Used by: QP3,NP2
Cause:
Remedy: Replace the servo amplifier.
------------------------------
Code: 120685AF
Display: TY-axis: Command uncompleted.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120685B0
Display: TY-axis: Power line open phase.
Used by: QP3,NP2
Cause:
Remedy: Check the servo amplifier power cable connection.
------------------------------
Code: 12068600
Display: TZ-axis: Cycle error!
Used by: QP3,NP2
Cause:
Remedy: TZ-axis: Check the servo motor, servo amp and wiring.
------------------------------
Code: 12068601
Display: TY-axis: Cycle error!
Used by: QP3,NP2
Cause:
Remedy: TY-axis: Check the servo motor, servo amp and wiring.
------------------------------
Code: 12068610
Display: Lifter ascent error!
第 686 页
Used by: QP3,NP2
Cause:
Remedy: Check if the lifer upper limit sensor is on, or if the remover lower limit sensor is off. Also check if
there is a delay in lifter ascent.
------------------------------
Code: 12068611
Display: Remover descent error!
Used by: QP3,NP2
Cause:
Remedy: Check if the lifter upper limit sensor is off, or if the lower limit sensor is on. Also check if there is
a delay in lifter descent.
------------------------------
Code: 12068612
Display: Remover chucking error!
Used by: QP3,NP2
Cause:
Remedy: Check if the remover's chucking sensor is on. Also check if there is a delay in the chucking
motion.
------------------------------
Code: 12068613
Display: Remover release cycle error!
Used by: QP3,NP2
Cause:
Remedy: Check if the remover's chucking sensor is off. Also check if there is a delay in the remover's
release motion.
------------------------------
Code: 12068614
Display: Remover hose ascent cycle error.
Used by: QP3,NP2
Cause:
Remedy: The remover hose was raised, but the upper limit sensor did not turn off within the required 3
second time period.
------------------------------
Code: 12068615
Display: Remover hose descent cycle error.
Used by: QP3,NP2
Cause:
Remedy: The remover hose was lowered, but the lower limit sensor did not turn off within the required 3
second time period.
------------------------------
Code: 12068616
Display: Clamper cylinder cycle error.
Used by: QP3,NP2
Cause: Even though the clamper cylinder operates, the status of the clamp cylinder open limit sensor
does not change.
Remedy: Check the operation of the clamper cylinder, or check that the clamp cylinder open limit sensor
triggers correctly.
------------------------------
Code: 12068800
Display: TZ-axis interlock error (TY-axis intermediate position).
Used by: QP3,NP2
第 687 页
Cause:
Remedy: Turn the TY-axis travel permit input and the tray supply input both off, and move the TY-axis to
a position where one of the inputs turns on.
------------------------------
Code: 12068801
Display: TZ-axis interlock error (no tray received).
Used by: QP3,NP2
Cause:
Remedy: Check if the drawer is triggering the tray supply sensor.
------------------------------
Code: 12068802
Display: TZ-axis interlock error (Y-axis at retract limit).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis is at its retract limit (TY-axis travel permit sensor on).
------------------------------
Code: 12068803
Display: TZ-axis interlock error (TY-axis at advance limit).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis is at its advance limit (tray pick-up sensor on).
------------------------------
Code: 12068804
Display: TZ-axis interlock error.
Used by: QP3,NP2
Cause:
Remedy: Check if the clamper cylinder open limit sensor is on.
------------------------------
Code: 12068810
Display: TY-axis interlock error (advanced).
Used by: QP3,NP2
Cause:
Remedy: Check if the tray pick-up sensor is on.
------------------------------
Code: 12068811
Display: TY-axis interlock error (retracted).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis retract permit sensor is on.
------------------------------
Code: 12068812
Display: TY-axis interlock error (TZ-axis position undefined).
Used by: QP3,NP2
Cause:
Remedy: Check if the TZ-axis is at tray shuttling height.
------------------------------
Code: 12068820
Display: Tray rejection error!
Used by: QP3,NP2
Cause:
Remedy: Check if the tray has been dropped during transfer to the reject position.
第 688 页