FUJI错误代码查询 - 第742页

Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again, use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as a faulty…

100%1 / 5282
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Over Instructed Z-Pulse" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The IN position was detected outside instructed Z-axis pulse range.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?94
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Zero Set Conditions Incomp" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine was unable to execute zero setting because the conditions for zero setting were not
met.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?95
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Tray remover alarm" (QP2)
Remover docking error!(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The operation of the tray remover is not correct. ? is the module number. "****" is the error
code.(QP2)
The removers at both stages are not attached to the lifter.(NP2,QP3)
Remedy: Check that the sensors around the tray remover are operating correctly.(QP2)
Return both removers to the lifters.(NP2,QP3)
------------------------------
Code: 12070?96
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Sent Atr Data w/o SENDAT" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Attribute data was transmitted even though no SENDAT command was received.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?97
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Sent Atr Data with Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Attribute data was transmitted after an error was reported in response to a SENDAT command.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 741 页
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?98
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Axis Incorrectly Specified" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The axis to perform an action has been incorrectly specified.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?99
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Program Trans before Reqst" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Program data has been transmitted without a program transmission request.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?9A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"1 Packt Over Prog Trans Lim" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The length of a single program data transmission packet is too long.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?9B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"1 Packt Ovr Atrib Trans Lim" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The length of a single program data transmission packet is too long.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
第 742 页
------------------------------
Code: 12070?9C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Reqed Attrib Data Incorrect" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The requested attribute data was incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?9D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Atrib D Trns before Req:PMC" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Attribute data was transmitted to the PMC without an attribute transmission request.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?9E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Data Parameter Size" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The transmitted parameter size is incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?9F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"M/C Soft Trans'd w/o Req'st" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Firmware data was transmitted without a firmware transmission request.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Use a reset-start to transmit the control software to the PMCs. If the problem is recurring,
issues such as a faulty PMC control board may be the cause.
------------------------------
Code: 12070?A0
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parametr Trans'd before Req" (QP2)
第 743 页