------------------------------ Code: 1207E?3D Display: "ICM (PMC?, SCU?) Error Code:********" (QP2) "Instruction to LLL failed" (QP2) Used by: QP242 Cause: Instruction to LLL failed. ? is the module n…
Remedy: Set the flux ejection quantity in the "Flux Cylinge Size" parameter in the Proper data.
------------------------------
Code: 1207E?37
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"SCU warning" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: SCU warning report.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?38
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC communication timeout" (QP2)
Used by: QP242
Cause: A timeout has occurred during communication with the PPC.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether the cable to the PPC is connected. Check the PPC for problems.
------------------------------
Code: 1207E?39
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Data overflow at PPC" (QP2)
Used by: QP242
Cause: PPC data overflow.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power off and on once, then perform measurements again. Make sure the cable
between the PPC and the load cell table is not broken.
------------------------------
Code: 1207E?3A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC measurement unstable" (QP2)
Used by: QP242
Cause: PPC measurement values are not stable.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power off and on once, then perform measurements again. If this error occurs
frequently, the PPC must be replaced.
------------------------------
Code: 1207E?3B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC Holdmode not set" (QP2)
Used by: QP242
Cause: The PPC hold mode has not been set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Change the PPC hold mode setting to 3.
------------------------------
Code: 1207E?3C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC Zero-tracking mode..." (QP2)
Used by: QP242
Cause: The PPC is operating in zero-tracking mode.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the PPC zero-tracking function off.
第 824 页
------------------------------
Code: 1207E?3D
Display: "ICM (PMC?, SCU?) Error Code:********" (QP2)
"Instruction to LLL failed" (QP2)
Used by: QP242
Cause: Instruction to LLL failed. ? is the module number. "****" is the error code.
Remedy: Change the LLL board.
------------------------------
Code: 1207E?3E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray not at retract pos." (QP2)
Used by: QP242
Cause: The TZ-axis has attempted to move but the prerequisite conditions are not being satisfied.
SCU I/O: X03D or X03E is ON, X017 is ON
MTU7: When X03D is ON, X01D is ON
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether or not the shuttle's extended position or the retract position sensor is ON. Check
that the tray storage confirmation sensor (tray's expulsion sensor) is not being blocked. If the shuttle is at
the extended position on a MTU-7, check that the TZ-axis interlock sensor is not being blocked.
------------------------------
Code: 1207E?3F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TZ axis not at org. pos." (QP2)
Used by: QP242
Cause: The TY-axis has attempted to move but the prerequisite conditions are not being satisfied.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the TY-axis movement sensor is not being blocked.
(SCU I/O: X03F TY MOVE OK POS... ON)
------------------------------
Code: 1207E?40
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Empty tray container full" (QP2)
Used by: QP242
Cause: Either the MTU-7's empty tray container is full or the tray eject sensor is being blocked.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the trays from the empty tray container or remove what is blocking the tray eject sensor.
------------------------------
Code: 1207E?41
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray D No. unknown" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Currently not supported. If this error occurs, please contact Fuji.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy:
------------------------------
Code: 1207E?42
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray collect not possible" (QP2)
Used by: QP242
Cause: The tray cannot be returned to the MTU-6 magazine because the tray's device number is
unknown.
第 825 页
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Either return the current tray to the magazine using the [POSITION] command or remove the
tray manually.
------------------------------
Code: 1207E?43
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray positioning sensor NG" (QP2)
Used by: QP242
Cause: The tray height positioning sensor for the tray that has been pulled has been executed but the
sensor will not turn ON or the sensor is already ON.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the state of the tray height positioning sensor.
------------------------------
Code: 1207E?44
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"X-axis measurement command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The LLL board may be carrying out another command. ? is the module number. "****" is the
error code.(QP2)
X-axis measurement command error.The LLL board may be carrying out another
command.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?45
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"X-axis measurement command processing error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP201,NP2,QP3
Cause: A command was issued to the LLL incorrectly. Or the LLL did not respond correctly. ? is the
module number. "****" is the error code.(QP2)
X-axis measurement command processing error. A command was issued to the LLL incorrectly. Or
the LLL did not respond correctly.(NP2,QP3)
Remedy: Check that the LLL board and the LLL sensor are connected correctly.(QP2,NP2,QP3)
------------------------------
Code: 1207E?46
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Y-axis measurement command error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP201,NP2,QP3
Cause: The LLL board may be carrying out another command. ? is the module number. "****" is the
error code.(QP2)
Y-axis measurement command error. The LLL board may be carrying out another
command.(NP2,QP3)
Remedy: Reboot the machine and retry the operation.
------------------------------
Code: 1207E?47
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Y-axis measurement command processing error" (QP2)
Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3