FUJI错误代码查询 - 第845页

"****" indicates the error code. Remedy: Check that the servo unit is properly connected. ------------------------------ Code: 1207F?51 Display: "SCU?(PMC?,ICM) Error Code:********" "TY-Axis Memo…

100%1 / 5282
Code: 1207F?47
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Transmission Timeout"
Used by: QP242
Cause: The command's first character was not input within the specified time (30 ms).
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?48
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Transmission Timeout"
Used by: QP242
Cause: The time between characters exceeds 100 ms.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?49
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?4A
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Axis Alarm Still Occuring"
Used by: QP242
Cause: A command was received before the machine was reset.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?4B
Display: "SCU?(ICM,PMC?) Error Code:********"
"TY-Axis Servo Alarm Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?50
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Comm Error"
Used by: QP242
Cause: Cannot communicate with the servo unit.
"?" indicates the module number (QP2).
第 844 页
"****" indicates the error code.
Remedy: Check that the servo unit is properly connected.
------------------------------
Code: 1207F?51
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?52
Display: "SCU?(PMC?,ICM) Error Code:********"
"The TY-Axis Servo is OFF or an alarm is active."
Used by: QP242
Cause: The TY-axis servo is off or an alarm is active.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: If the TY-axis servo is off, check that the servo controller is being supplied with power. If an
alarm is active, clear the alarm and restart operation.
------------------------------
Code: 1207F?53
Display: "SCU?(PMC?,ICM) Error Code:********"
"A TY-axis servo parameter have not been set."
Used by: QP242
Cause: Check the parameters for the TY-axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Set the TY-axis servo parameters, supply power and restart operation.
------------------------------
Code: 1207F?54
Display: "SCU?(PMC?,ICM) Error Code:********"
"Cancellation by TY-Axis stop command."
Used by: QP242
Cause: Axis operation terminated because a separate error occurred during communication.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?55
Display: "SCU?(PMC?,ICM) Error Code:********"
"Error prior to TY-Axis Encorder Counter Operation"
Used by: QP242
Cause: The machine attempted to take an encoder count before the current count had been confirmed.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?56
Display: "SCU?(PMC?,ICM) Error Code:********"
第 845 页
"TY-Axis Encorder Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?57
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Encorder Counter Recieving Error"
Used by: QP242
Cause: An error occurred at the TY-axis servo controller when receiving data.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?58
Display: "SCU?(PMC?,ICM) Error Code:********"
"Disconnected TY-Axis"
Used by: QP242
Cause: TY-axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?59
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Controller Timeout"
Used by: QP242
Cause: The TY-axis timed out.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?5A
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Controller Busy"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2)
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?5B
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Controller Axis Stop"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
第 846 页