Code: 12111001 Display: Command error. Used by: Cause: A command which can not be recognized was send to the conveyor control board. Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control bo…

100%1 / 5282
damaged.
------------------------------
Code: 1211007b
Display: Machine type error.
Used by:
Cause: This function can only be called in a machine with an analog environment.
Remedy: Reinstall the software, because the initial installation could have failed.
If this error cannot be corrected, obtain the trace data and contact Fuji.
------------------------------
Code: 1211007c
Display: Machine type error.
Used by:
Cause: This function can only be called in a machine with an SERCOS environment.
Remedy: Reinstall the software, because the initial installation could have failed.
If this error cannot be corrected, obtain the trace data and contact Fuji.
------------------------------
Code: 1211007d
Display: Movement interpolation error.
Used by:
Cause: Movement interpolation has occurred for the same axis.
Remedy: Reinstall the software, because the initial installation could have failed.
If this error cannot be corrected, obtain the trace data and contact Fuji.
------------------------------
Code: 1211007e
Display: Movement interpolation error.
Used by:
Cause: For the selected axes, movement interpolation cannot be be done because the axes are not on the
same servo controller board.
Remedy: Reinstall the software, because the initial installation could have failed.
If this error cannot be corrected, obtain the trace data and contact Fuji.
------------------------------
Code: 1211007f
Display: Process error.
Used by:
Cause: A function only supported by the RTX process was called.
Remedy: Reinstall the software, because the initial installation could have failed.
If this error cannot be corrected, obtain the trace data and contact Fuji.
------------------------------
Code: 12110080
Display: Process error.
Used by:
Cause: A function only supported by the Win32 process was called.
Remedy: Reinstall the software, because the initial installation could have failed.
If this error cannot be corrected, obtain the trace data and contact Fuji.
------------------------------
Code: 12110081
Display: Axes stop demand.
Used by:
Cause: The axis movement was stopped by the application.
Remedy: Remove the cause of the error and resume operation.
------------------------------
第 879 页
Code: 12111001
Display: Command error.
Used by:
Cause: A command which can not be recognized was send to the conveyor control board.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111002
Display: Data error.
Used by:
Cause: Incorrect data was send to the conveyor control board.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111003
Display: CRC error.
Used by:
Cause: An error has occurred during communication.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111004
Display: Cover opening.
Used by:
Cause: Conveyor's cover is open.
Remedy: Closing a conveyor's cover.
------------------------------
Code: 12111005
Display: Emergency Stop.
Used by:
Cause: The emergency stop button was pressed.
Remedy: Reset the emergency stop button.
------------------------------
Code: 12111006
Display: Encoder error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 2.8 V.
Remedy: Contact Fuji. Because there is possibility that the position data of the encoder disappeared.
------------------------------
Code: 12111007
Display: Battery error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 3.0 V.
Remedy: Exchange a battery of the encoder for the backup.
------------------------------
Code: 12111009
Display: Conveyor's width error.
Used by:
Cause: Conveyor's width which crosses a maximum or a minimum value was set.
Remedy: After confirming a maximum and a minimum value, input once more.
------------------------------
第 880 页
Code: 1211100A
Display: Movement error.
Used by:
Cause: The operation didn't end normally by some factor.
Remedy: After removing an extraordinary factor, operation be resumed.
Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 1211100B
Display: Communication error.
Used by:
Cause: Communication between the host and the conveyor control board wasn't established in the time.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111014
Display: Internal error.(Event error)
Used by:
Cause: The event object became invalid.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111015
Display: Internal error.(Timeout)
Used by:
Cause: The communication didn't complete to the conveyor control board with the host in the time.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111016
Display: Internal error.(CRC error)
Used by:
Cause: An error has occurred during communication.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111017
Display: Internal error.(Retry over)
Used by:
Cause: Communication wasn't established to the conveyor control board after retry.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111018
Display: Internal error.(Shared memory error)
Used by:
Cause: The version of the modules may not be adjusted.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111019