FUJI错误代码查询 - 第881页
Code: 1211100A Display: Movement error. Used by: Cause: The operation didn't end normally by some factor. Remedy: After removing an extraordinary factor, operation be resumed. Contact Fuji if this error cannot be co…
Code: 12111001
Display: Command error.
Used by:
Cause: A command which can not be recognized was send to the conveyor control board.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111002
Display: Data error.
Used by:
Cause: Incorrect data was send to the conveyor control board.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111003
Display: CRC error.
Used by:
Cause: An error has occurred during communication.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111004
Display: Cover opening.
Used by:
Cause: Conveyor's cover is open.
Remedy: Closing a conveyor's cover.
------------------------------
Code: 12111005
Display: Emergency Stop.
Used by:
Cause: The emergency stop button was pressed.
Remedy: Reset the emergency stop button.
------------------------------
Code: 12111006
Display: Encoder error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 2.8 V.
Remedy: Contact Fuji. Because there is possibility that the position data of the encoder disappeared.
------------------------------
Code: 12111007
Display: Battery error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 3.0 V.
Remedy: Exchange a battery of the encoder for the backup.
------------------------------
Code: 12111009
Display: Conveyor's width error.
Used by:
Cause: Conveyor's width which crosses a maximum or a minimum value was set.
Remedy: After confirming a maximum and a minimum value, input once more.
------------------------------
第 880 页
Code: 1211100A
Display: Movement error.
Used by:
Cause: The operation didn't end normally by some factor.
Remedy: After removing an extraordinary factor, operation be resumed.
Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 1211100B
Display: Communication error.
Used by:
Cause: Communication between the host and the conveyor control board wasn't established in the time.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111014
Display: Internal error.(Event error)
Used by:
Cause: The event object became invalid.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111015
Display: Internal error.(Timeout)
Used by:
Cause: The communication didn't complete to the conveyor control board with the host in the time.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111016
Display: Internal error.(CRC error)
Used by:
Cause: An error has occurred during communication.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111017
Display: Internal error.(Retry over)
Used by:
Cause: Communication wasn't established to the conveyor control board after retry.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control board could be
damaged.
------------------------------
Code: 12111018
Display: Internal error.(Shared memory error)
Used by:
Cause: The version of the modules may not be adjusted.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111019
第 881 页
Display: Internal error.(Command error)
Used by:
Cause: After executing a command, it becomes extraordinary ending.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 1211101A
Display: Internal error.(Failed to send command.)
Used by:
Cause: A command could not be send to the conveyor control board.
Remedy: After confirming whether or not the connection cable at the communication port doesn't come,
operation be resumed.
------------------------------
Code: 1211101F
Display: Internal error.(Failed to start dll.)
Used by:
Cause: Dll wasn't possible to start normally.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111020
Display: Internal error.(Failed to terminate dll.)
Used by:
Cause: Dll wasn't possible to terminate normally.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111028
Display: Internal error.(Abnormal parameter.)
Used by:
Cause: Because the parameter when using an API was an incorrect, the function could not be executed.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12111032
Display: Internal error.(Communication port error.)
Used by:
Cause: Conveyor control function wasn't possible to do the opening or the closing of the communication
port.
Remedy: Contact Fuji if this error cannot be corrected, because the conveyor control function could be
damaged.
------------------------------
Code: 12112001
Display: DxShell internal error.(Received data error.)
Used by:
Cause: The received data is incorrect data.
Remedy: Contact Fuji if this error cannot be corrected, because the LON communication function could
be damaged.
------------------------------
Code: 12112002
Display: DxShell internal error.(Queue buffer full.)