FUJI错误代码查询 - 第889页
Cause: Abnormal primary circuit detected. All of the detected power circuit data is abnormal. Remedy: The power supply voltage could be fluctuating. Check the power supply voltage. Replace Servo amplifier with a new one …
Remedy: After checking the settings, reinstall the recovery media software.
If this error cannot be corrected, the hard disk could be damaged.
------------------------------
Code: 1220001f
Display: Parameter error.
Used by:
Cause: An incorrect parameter is set in the servo initialization file, or the servo initialization file is
corrupted.
Remedy: After checking the settings, reinstall the recovery media software.
If this error cannot be corrected, the hard disk could be damaged.
------------------------------
Code: 12200020
Display: Cannot access a file.
Used by:
Cause: The displayed file is possibly corrupted.
Remedy: After checking the settings, reinstall the recovery media software.
If this error cannot be corrected, the hard disk could be damaged.
------------------------------
Code: 12200021
Display: Program and DLLs do not correspond.
Used by:
Cause: The current program and DLLs are not appropriate, or the installation failed.
Remedy: Reinstall the recovery media software.
If this error cannot be corrected, the hard disk could be damaged.
------------------------------
Code: 12200022
Display: SERCOS communication error.
Used by:
Cause: Communication is not performed if the digital operator was attached when communication
initialization is performed, or the SERCOS drive software version does not match.
Remedy: Disconnect the digital operator and restart the machine, or check the SERCOS drive software
version.
If this error cannot be corrected, the SERCOS drive could be damaged.
------------------------------
Code: 12200023
Display: SERCOS loop disconnected.
Used by:
Cause: The SERCOS loop is disconnected, a fiber optic connector is broken, or the fiber optics are
connected in the wrong order.
Remedy: Check the order of the fiber optic connections, and the condition of the connectors.
If this error cannot be corrected, the SERCOS drive could be damaged.
------------------------------
Code: 12200030
Display: Servo amplifier error.
Used by:
Cause: Parameters are corrupted. Servo pack EEPROM data is abnormal.
Remedy: Replace Servo amplifier with a new one, because the servo amplifier could be damaged.
------------------------------
Code: 12200031
Display: Servo amplifier error.
Used by:
第 888 页
Cause: Abnormal primary circuit detected. All of the detected power circuit data is abnormal.
Remedy: The power supply voltage could be fluctuating. Check the power supply voltage.
Replace Servo amplifier with a new one if there is no abnormal power supply conditions, because
the servo amplifier could be damaged.
------------------------------
Code: 12200032
Display: Servo amplifier error.
Used by:
Cause: Abnormal parameter setting. A parameter is set outside the valid range for that parameter.
Remedy: Check all of the parameter settings for any values outside the valid range.
Replace Servo amplifier with a new one if all of the settings are correct, because the servo amplifier
could be damaged.
------------------------------
Code: 12200033
Display: Servo amplifier error.
Used by:
Cause: Matching error. The motor and servo pack capacities do not match.
Remedy: Check to make sure that there are no wiring problems.
Replace Servo amplifier with a new one if no abnormalities are found, because the servo amplifier
could be damaged.
------------------------------
Code: 12200034
Display: Servo amplifier error.
Used by:
Cause: Current overload or the heat sink is too hot. The current meter has detected a surge, or the servo
pack's heat sink is too hot.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Replace Servo amplifier with a new one if no errors are found, because the servo amplifier could be
damaged.
------------------------------
Code: 12200035
Display: Servo amplifier error.
Used by:
Cause: Regenerative error. Either the regenerative resistance wiring is disconnected, or a regenerative
transistor is damaged.
Remedy: Replace Servo amplifier with a new one, because it is possible that the servo amplifier is
damaged.
------------------------------
Code: 12200036
Display: Servo amplifier error.
Used by:
Cause: Regenerative overload. The regenerative energy is more than the regenerative resistance capacity.
Remedy: The axis rotating speed is too fast, or the regenerative resistance capacity is incorrect.
Replace Servo amplifier with a new one if no abnormalities are found, because the servo amplifier
could be damaged.
------------------------------
Code: 12200037
Display: Servo amplifier error.
Used by:
Cause: Overvoltage. The base DC voltage is abnormally high.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
第 889 页
Replace Servo amplifier with a new one if no abnormalities are found, because the servo amplifier
could be damaged.
------------------------------
Code: 12200038
Display: Servo amplifier error.
Used by:
Cause: Undervoltage. The base DC voltage is too low.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Replace Servo amplifier with a new one if no abnormalities are found, because the servo amplifier
could be damaged.
------------------------------
Code: 12200039
Display: Servo amplifier error.
Used by:
Cause: Acceleration rate. The motor is rotating abnormally high.
Remedy: The speed setting could be abnormally high. Check the parameter settings.
Replace Servo amplifier with a new one if no abnormalities are found, because the servo amplifier
could be damaged.
------------------------------
Code: 1220003a
Display: Servo amplifier error.
Used by:
Cause: Momentary maximum torque. Operation was performed for several seconds at significantly over
the rated torque.
Remedy: Check to ensure that there is no interference or that the axis movement is not impeded. In
addition, check to ensure that none of the motor power lines are broken (U,V,W), or that there are no
shorts.
------------------------------
Code: 1220003b
Display: Servo amplifier error.
Used by:
Cause: DB overload. During dynamic braking, the rotational energy is more than the DB resistance
capacity.
Remedy: The emergency stop process could be incorrect. If this occurs frequently, replace Servo amplifier
with a new one.
------------------------------
Code: 1220003c
Display: Servo amplifier error.
Used by:
Cause: Initial resistance overload. The base power has been repeatedly turned on and off.
Remedy: Check for a short in the power line, or if the wire is broken, when this condition occurs.
Replace Servo amplifier with a new one if no abnormalities are found, because the servo amplifier
could be damaged.
------------------------------
Code: 1220003d
Display: Servo amplifier error.
Used by:
Cause: Heat sink is too hot. The heat sink for the servo pack is too hot.
Remedy: Check for abnormalities in the base circuitry or in the wiring for the motor power.
Replace Servo amplifier with a new one if no abnormalities are found, because the servo amplifier
could be damaged.
第 890 页