FUJI错误代码查询 - 第894页

Cause: The deceleration time setting is outside the valid range. Remedy: Reinstall the software because the initial installation could have failed. ------------------------------ Code: 12200057 Display: Jerk ratio is out…

100%1 / 5282
Code: 1220004D
Display: HOME sensor error.
Used by:
Cause: The HOME sensor is detected at the wrong timing in the homing.
Remedy: The noise may be mixed in the HOME sensor input terminal.
Please check the dirt of a HOME sensor light input part,
Please check that poor connection has not occurred between the SERVO board (amplifier) and a
HOME sensor.
------------------------------
Code: 12200050
Display: Board error.
Used by:
Cause: The servo board set in the servo initialization file is not supported.
Remedy: Check the setting in the servo initialization file, and that the servo control board is correct.
If no abnormalities are found, the board could be damaged.
------------------------------
Code: 12200051
Display: Failed to create object.
Used by:
Cause: Failed to create a servo object.
Remedy: Reinstall the software because the initial installation could have failed.
If this error is not corrected, the servo control board could be damaged.
------------------------------
Code: 12200052
Display: Abnormal ADC number.
Used by:
Cause: The ADC number setting does not exist.
Remedy: Check the value in the servo initialization file.
If no abnormalities are found, reinstall the software.
------------------------------
Code: 12200053
Display: Axis number is outside the valid range.
Used by:
Cause: An invalid value has been set in the parameter's argument (axis number).
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200054
Display: Board number is outside the valid range.
Used by:
Cause: The setting for the servo controller board number is incorrect.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200055
Display: Acceleration time is outside the valid range.
Used by:
Cause: The acceleration time setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200056
Display: Deceleration time is outside the valid range.
Used by:
第 893 页
Cause: The deceleration time setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200057
Display: Jerk ratio is outside the valid range.
Used by:
Cause: The jerk ratio setting is outside the valid range (1-100).
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200058
Display: Position is outside the valid range.
Used by:
Cause: The position parameter setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200059
Display: Abnormal GAIN-INDEX.
Used by:
Cause: The GAIN-INDEX setting (Moving, Settling, ...)is invalid.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1220005a
Display: Abnormal GAIN table number.
Used by:
Cause: The GAIN table number setting is invalid.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1220005b
Display: Speed is outside the valid range.
Used by:
Cause: The traveling speed setting is outside the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1220005c
Display: Axis number is outside the valid range.
Used by:
Cause: Unable to reference the gain table as the specified axis number is invalid.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1220005d
Display: No parameter.
Used by:
Cause: A parameter is not set in the GAIN table ID.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 1220005e
Display: Previous goal position is not set.
Used by:
Cause: The movement operation cannot be performed because the previous goal position is not set so it
cannot be referenced.
Remedy: Reinstall the software because the initial installation could have failed.
第 894 页
------------------------------
Code: 1220005f
Display: Abnormal AD converter.
Used by:
Cause: A setting for the AD converter is invalid.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200060
Display: Abnormal measurement range.
Used by:
Cause: The setting for the AD converter measurement range is outside of the valid range.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200061
Display: Abnormal IDN communication.
Used by:
Cause: SERCOS IDN communication that is not supported has occurred.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200062
Display: Abnormal Pno communication.
Used by:
Cause: SERCOS Pno communication that is not supported has occurred.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200063
Display: Abnormal access.
Used by:
Cause: The maximum number of simultaneous Pno and IDN access possible to the SERCOS drive has
been exceeded.
Remedy: Reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200064
Display: Emergency stop condition.
Used by:
Cause: An axis has been given instructions to move while in emergency stop condition.
Remedy: Attempt to move the axes after releasing the emergency stop condition. If the same error occurs,
reinstall the software because the initial installation could have failed.
------------------------------
Code: 12200065
Display: Servo off condition.
Used by:
Cause: An axis has been given instructions to move while in the servo off condition.
Remedy: Check to ensure that the servo on signal is not disconnected.
If that does not clear the error, reinstall the software because the initial installation could have
failed.
------------------------------
Code: 12200066
Display: Hold signal on.
Used by:
Cause: An axis has been given instructions to move while in the HOLD signal condition.
第 895 页