EUKYX-199-5100_G5S2_Instruction_Vol5_E - 第186页

199-5100 Chapt er 5 Cable Connection Diagram This chapter describes the cable connection diagram. As this contains highly sophisticated contents, it should carefully be referred to. 1. Wire Harness Diagram EUKYX

100%1 / 191
EUKYX
4-70199-5100
2.55 Multi-Functional Head Section Circuit 2 [Type D]
2.55 Multi-Functional Head Section Circuit 2 [Type D]
1
2
CN9
1
2
3
CN10
1
2
3
CN11
CN12
1
2
3
CN13
1
2
3
CN14
U07D
Connector PCB
GND
OUT1
+V
B143-1(R)
B144-1
3
GND
+V
Y145-1
4
GND
+V
Y146-1
1
2
3
4
B143-1(T)
GND
+V
GND
+V
GND
OUT1
+V
+
-
+
OUT
-
+
-
+
OUT
-
GND
+24V
L2_OR-
GND
+24V
L2_H_SENS
GND
+24V
L1_OR-
GND
+24V
L1_H_SENS
L2_VAC
L2_VAC_BRK
+24V
+24V
L1_VAC
L1_VAC_BRK
+24V
+24V
:1
:2
:3
:1
:2
:3
:1
:2
:1
:2
:4
:3
:4
:3
CN2
1
2
3
4
5
6
7
8
9
10
11
17
18
19
12
13
14
15
20
21
22
23
24
25
26
27
28
29
31
32
33
34
35
36
37
38
39
30
40
41
42
43
44
MRR_1
P5G_1
MR_1
P5_1
MRR_2
MR_2
MRR_3
MR_3
MRR_4
MR_4
U07D
Connector PCB
L1_FLOW_3
L2_FLOW_1
L2_FLOW_2
L2_FLOW_3
L3_FLOW_1
L1_H_SENS
L1_VAC
L1_VAC_BRK
L2_VAC
L2_VAC_BRK
L3_VAC
L3_VAC_BRK
CN15
1
2
3
CN16
1
2
3
CN17
1
2
3
4
GND
+V
GND
+V
GND
OUT1
+V
+
-
+
OUT
-
GND
+24V
L3_OR-
GND
+24V
L3_H_SENS
L3_VAC
L3_VAC_BRK
+24V
+24V
:1
:2
:3
:1
:2
:4
:3
CN19
1
2
4
5
GND
L1_FLOW_1(OUT)
+24V
3
L1_FLOW_1(EXT IN)
L1_FLOW_2(OUT)
CN18
1
2
4
5
N301
GND
OUT
Parts fall detection
GND
L1_FLOW_1(OUT)
+24V
3
L1_FLOW_1(EXT IN)
L1_FLOW_2(OUT)
---
IN
+V
CN20
1
2
4
5
GND
L1_FLOW_1(OUT)
+24V
3
L1_FLOW_1(EXT IN)
L1_FLOW_2(OUT)
16
SW1_1
1 8
2 7
3 6
MRR_5
P5G_2
MR_5
P5_2
MRR_6
MR_6
L1_OR-
L2_OR-
L3_OR-
L2_H_SENS
L3_H_SENS
L1_FLOW_1
L1_FLOW_2
SW1_2
SW1_3
HEAD connection
(Light receiving side)
(Projected side)
Height detection
Height detection
1L Axis.
Overrun sensor
Vacuum break valve
Multifunction head
Nozzle 1 side
confirmation
Vacuum valve
1
ON
2 3 4
U07D Board SW1 Configuration
B143-2(R)
B144-2
Y145-2
Y146-2
B143-2(T)
(Light receiving side)
(Projected side)
Height detection
Height detection
2L Axis.
Overrun sensor
Vacuum break valve
Vacuum valve
B143-3(R)
B144-3
Y145-3
Y146-3
B143-3(T)
(Light receiving side)
(Projected side)
Height detection
Height detection
3L Axis.
Overrun sensor
Vacuum break valve
Vacuum valve
Multifunction head
Nozzle 2 side
Multifunction head
Nozzle 3 side
X0709
X0710
X0711
X0713
X0714
Y145
Y145X0712
B143
B143
X0702
X0716
X0717
Y145X0715
B143
X0718
L3_FLOW_3
L3_FLOW_2
KYX-000-CC-082-1
199-5100
Chapter 5
Cable Connection Diagram
This chapter describes the cable connection diagram.
As this contains highly sophisticated contents, it should carefully
be referred to.
1. Wire Harness Diagram
EUKYX
EUKYX
5-1199-5100
1. Wire Harness Diagram
1. Wire Harness Diagram
1.1 Wire Harness general view
A
C
B
3101011C09
1101000100
3101011C01
1101001A46
1101000100
3101011C0H
1101000100
1101000100
1101000100
1101000100
1101000100
1101000100
1101000100
3101011C0J
1101000100
1101000100
1101000100
1101000100
1101000100
1101000100
1101000100
1101001A46
3101011C0G
1101001A46
3101011C0F
1101001A46
1101000100
2101011C94
1101000100
1101000100
1101000100
1101000100
1101000100
3101011C0C
1101000100
1101000100
1101000100
2101011C95
1101000100
1101000100
1101000100
1101000100
1101000100
3101011C0E
1101000100
1101000100
3101011C02
1101000100
1101000100
2101001A45
2101001A45
3101011C03
1101000101
1101000101
OP
OP
1101000100
1101000100
1101000100
1101000100
CPU2BOX_U82 X8203
1101001A46
CPU2BOX_U82 X8204
1101001A46
TB:DC
2101001A45
3101011C90
CPU2BOX U85 DN
1101001A46
3101011C8Y
1101001A46
3101011C91
2101001A45
3101011C00
3101011C0L
1101001A46
3101011C0A
OP
2101001A45
3101011C8Q
2101001A45
3101011C7K
1101000100
3101011C7L
1101000100
3101011C7J
1101000101
1101000101
3101011C7H
1101001A46
1101001A46
CN29
X0129 XLAMP
CN31
X0131 XFAN
M105
M106
CN24
X0124
X10126
X20126
B-XNST1-SFL
F-XNST1-SFL
X10126
X10126
X10124
X0151
CN51
CN23
X0123
X10126
X20126
B-XNST1-SFL
F-XNST1-SFL
X10126
X10126
X10126
X0152
CN52
CN17
X0117 S141
XS111F
X0638
CN18
X0118 XS111B
X0638
CN19
X0119 F-XNST-1
F-XNST-2
XUP1
XUP2
XUP3
CN20
X0120 F-XNST-3
F-XNST-4
XUP4
CN21
X0121 B-XNST-1
B-XNST-2
XUP1
XUP2
XUP3
CN22
X0122 B-XNST-3
B-XNST-4
XUP4
CN26
X0126 X10126
X20126
B-XNST1-SFL
F-XNST1-SFL
CN28
X0128 X10128
X20128
INPUT-B
OUTPUT-B
B239
X0150
CN50
X0147
CN47
B239
CN8
CN1
X0108
U01(UC18)
X8203
X8204
X1
X01X1
X2
X01X2
X0101
CN2
X0102
CN4
X0104
X30C1-F
CN10
X0110 XFAN
X8204
CN11
X0111 X0220
X0223
X0112
CN12
CN13
X0113 X30D1B
X0130
CN30
X0148
CN48
CN14
X0114 X30D1F
X0132
CN32
X0149
CN49
CN25
X0125 X2753
X22753
X12753
X2761
CN15
X0115 X10115
X10116
X0116
CN16
X85DN
X0201
Intensive Board
Board
"Overall Feeder" Relay (Front) X30C1-F
U02 Head I/O PCB CN1
CPU2BOX Cooling FAN M177
U02 Head I/O PCB CN20
U02 Head I/O PCB CN23
After"Overall Connector" X30D1B
Before"Overall Connector" X30D1F
Relay Board U27 CN53
Relay Board U27 CN61
RAfter Operation Switch Panel Relay
X10115
Before Operation Switch Panel Relay
X10116
Pressure Switch S141
F READY(B2) S111F
Overall Component Rejection (B2) Y0638 / High-Speed, Multi-Functional (B2) Y0639
F READY(B1) S111B
Overall Component Rejection (B1) Y0938 / High-Speed, Multi-Functional (B1) Y0939
Nozzle Stocker 1 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker 2 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker Shutter Open/Close / Nozzle Stocker 1 UP
Nozzle Stocker 2 UP
Nozzle Stocker 3 UP
Rejected Component Box Detection Sensor (Front Side) B239
Nozzle Stocker 3 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker 4 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker 4 UP
Nozzle Stocker 1 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker 2 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker Shutter Open/Close / Nozzle Stocker 1 UP
Nozzle Stocker 2 UP
Nozzle Stocker 3 UP
Rejected Component Box Detection Sensor (Rear Side) B239
Nozzle Stocker 3 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker 4 Lower limit Detection / Shutter Close Check / Clamp Check
Nozzle Stocker 4 UP
Surge Protector F200 Alarm Relay
Feeder Power Relay K75,K77 _ON Relay
After "Nozzle Stocker for Multi-Functional Nozzle" Coplarnarity Error Detection
After "Nozzle Stocker for Multi-Functional Nozzle" Coplarnarity Error Detection
Relay for Front and Rear I/F Section Lane-A
Relay for Front and Rear I/F Section Lane-A
Front and Rear I/F Section Lane-B
Front and Rear I/F Section Lane-B
Feeder Base Up/Down B2 Relay
Cart Specified Position Check B2-2
Positioning Lock Check B2 (OP)
Positioning Upper Limit Detection B2
Pick-up Error Component Detection REAL B2
Feeder Hook Undone Check B2
Positioning Drop Prevention B2 (OP)
Feeder Base Up/Down B1 Relay
Cart Specified Position Check B1-2
Positioning Lock Check B1 (OP)
Positioning Upper Limit Detection B1
Pick-up Error Component Detection REAL B1
Feeder Hook Undone Check B1
Positioning Drop Prevention B1 (OP)
Tower Light Relay
Ceiling Fan Relay
Case Lower Fan Rear M105
Case Lower Fan Front M106 (OP)
Cable001