WEST•BOND MODEL 454647E SER IES INSTRUCTION MANUAL 6 ACCESSORY DESCRIPTIONS The specifications define Feature s that add additional capabilities or utilities to the basic machine models, and cross referen ce those models…

100%1 / 126
WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
5
PRODUCT OVERVIEW
Modes of Operation
FULL-AUTO OR HALF-AUTO
This mode is toggled by Key 8
Full-Auto: Start by G Key or Ball Button or Z Encoder. Lock manual X-Y slides and bond all
bonds of this wire. Pausing is controlled by Inhibit Auto described above.
Half-Auto: Controlled by G Key or Ball Button or Z Encoder. This is a press and release
sequence with pauses at each search and loop elevation.
I
NCH MODE
Start by Zero Key. Executes Half-Auto mode except proceeds down in slow steps from each
search to contact while key is held. Available any time tool is stopped.
Definitions of Models in this Series
All E Series machine models are finished with selected materials and protective coatings to prevent
electrostatic discharge to user's work piece.
M
ODEL NO. 4546E
This machine with single wedge bond tool head, Assembly No. 9004, with angled clamp
Assembly No 9048 and overhead clamp Assembly No 9049, for bonding by either wedge method.
M
ODEL NO. 4546EX
This machine, specified as Model 4546E, except without base.
M
ODEL NO. 454647E
This machine with two bond tool heads, Assembly No 9004 with the two clamp assemblies for
wedge bonding as above, and with tool head Assembly No 9044 for ball bonding, all convertible.
M
ODEL NO. 454647EX
This machine specified as Model 454647E, except without base.
M
ODEL NO. 4700E
This machine with one tool head Assembly No 9044 with K~Sine Transducer, Model No. 34-C,
for ball-wedge applications. Software also allows spaced, single-ball bonding.
M
ODEL NO. 4700EX
This machine specified as Model 4700E, except without base.
Services
Compressed air, regulated to 50 psi, is required. Connection is via 1/4-inch tubing.
Electrical service required is 50-60 Hz, single phase, either 115 VAC or 230 VAC; however, input must be
configured at the factory for 230 VAC. A fuse and three-prong power cord connector are provided for 115
VAC: For 230 VAC, these must be changed to conform to local requirements.
Dimensions
"E" Series machine size is 24.218" wide x 22.297" deep x 11.000" high, exclusive of microscope, or
15.000" in height to scope eyepieces. Weight is 75 lb. uncrated, or 110 lb. crated.
"EX" Series machine size is 22.312" wide x 16.500" deep x 6.000" high above work plane, exclusive of
microscope, or 10.0" high from work plane to scope eyepieces. Weight is 55 lb. uncrated, or 90 lb. crated.
WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
6
ACCESSORY DESCRIPTIONS
The specifications define Features that add additional capabilities or utilities to the basic machine models,
and cross reference those models with which the Features may be combined.
Non Heated Workholder: Non-rotating Epoxy Transfer &
Die Placement workholder for substrates up to 1.000" x
1.000", with mechanical clamp and adjustable back rails:
Assembly No. 3600.018
Non Heated Workholder: Non-rotating workholder for
substrates up to 1.000" x 1.000". Work piece is held by
mechanical clamp, with 2 Position, 2.000" x 2.000"
fluoroware supports. Assembly No. 3600.220
K~1200D, Temperature Controller: A 400 watt
microprocessor-based Temperature Controller provides
precise control with a minimum of set-up. The K~1200D is
a programmable controller linked to the workholder heating
elements through two solid state relays. The controller
offers flexibility, while the solid state relays offer
dependability. K~1201D is a 600 watts version for larger
applications.
Free Furnace Workholders:
This furnace is free in the sense that it is not connected to
the machine but may be readily inter-changed with the Free
Anvil normally used for ultrasonic bonding, giving
workpiece heat capability to any machines of the 4K, 5K or
7K Series.
-45C: Free Furnace Workholder: for substrates up to
1.000" x 1.000", mechanical clamp, adjustable backstop
with rotating die mirror presentation.
Assembly No. 3800.009
-45C.358 Free Furnace Workholder: for substrates up to
1.000" x 1.000", mechanical clamp, adjustable backstop,
with cavity inert atmosphere. Adjustable height, rotating
2.00" x 2.00" fluoroware support.
Assembly No. 3800.358
WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
7
ACCESSORY DESCRIPTIONS
-45G.353 Free Furnace Workholder: 2" x 2" substrates,
mechanical clamp, adjustable backstop, cavity inert
atmosphere. With 2" x 2" fluoroware die presentation.
Assembly No. 3800.353
-45G.402 Free Furnace Workholder: 2" x 2" substrates,
mechanical clamp, adjustable backstop, cavity inert
atmosphere. With 2" x 2" fluoroware support and rotating die
mirror presentation.
Assembly No. 3800.402
K~1300 Gas Flow Assembly: Comprised of K~1310 Gas
Flow Control and K~1320 Laminar Flow Nozzle. Used to
compliment W
ESTBOND Cavity Inert Atmosphere Work
holders for Eutectic die attachment.
K~1310 Gas Flow Control: The operator, by means of an
on/off footswitch, releases the gas to the work area.
Immediately after the scrub cycle stops, the footswitch is
activated and the die is showered with cool forming gas. A
manual adjustment is provided to meter the amount of gas
to be released.
K~1311 Vacuum Flow Control: The operator, by means of
an Off/On footswitch, can disengage the vacuum to the
work area releasing the part to replace with another. A
vacuum gauge on the front of the control box displays the
pressure in inches of Mercury.