wire-bonder.pdf - 第41页
WEST•BOND MODEL 454647E SER IES INSTRUCTION MANUAL 35 OPERATION Monitor or Microscope This option allows the operato r to select betw een using the microscope or the monitor for bond placement. When toggled by key 9, t h…

WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
34
OPERATION
Adjust the Crosshairs
Once the wire has been successfully bonded off, the system will prompt the operator to adjust the
crosshairs on the external crosshair generator. If the bond does not stick then the operator can choose to
bond again by pressing key A.
ADJUST VIDEO CROSSHAIRS
--> Adjust video crosshair onto bond
A=Bond again G=
O
K
Use the digi-switches on the crosshair generator to move the crosshairs up and down or left and right.
Key G is then pressed to accept the crosshair settings.
ϑ To call “Adjust crosshairs” Menu
From the H
OME menu press 6 (THREAD / BOND-OFF) and then press 0 or G to BOND-OFF wire.
Key Format:
Escape
1
2
Home
3
4
5
6
7
8
9
Bond
again
A
0
OK
G

WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
35
OPERATION
Monitor or Microscope
This option allows the operator to select between using the microscope or the monitor for bond
placement. When toggled by key 9, the bond tool moves along the Y Axis between the target position
above the bond, and a retracted position out of camera view. The display on the Menu is the option to be
switched to. (i.e. key 9 = Monitor; pressing key 9 will switch to monitor operation).
Using the monitor, the operator targets the bond using the crosshairs on the television monitor screen to
begin the bonding sequence. Using the microscope, the operator bonds by direct view of the tool through
the microscope, however, in this setting, the tool head blocks the camera’s view.
*NOTE: Critical Bond (page 75) is ignored when in the Microscope mode.
ALIGN BOND 1 of 2 USE MONITOR.
Device 1 of 30
7=Lock X 8=More options 9=Microscope
A=Feed 0=Manual bond G=Full-Auto
Machine is now M
ONITOR in mode. Pressing
key 9 will convert the machine to M
ICROSCOPE mode.
ALIGN BOND 1 of 2 USE MICROSCPE.
Device 1 of 30
7=Lock X 8=More options 9=Monitor
A=Feed 0=Manual bond G=Full-Auto
Machine is now in M
ICROSCOPE mode. Pressing key
9 will convert the machine to M
ONITOR mode.
ϑ To change between “Monitor or Microscope”
From the H
OME menu press 9 (MONITOR / MICROSCOPE) to toggle between modes.
Key Format:
1
Go To
Device/Type
2
Home
3
Edit
4
Info
5
Thread /
Bond-Off
6
Lock X
7
More
Options
8
Microscope /
Monitor
9
Feed
A
Manual
Bond
0
Full Auto
G

WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
36
OPERATION
Go To
This option allows the operator to specify where the bonding sequence should begin. Specify either by
the Device #, Type #, then Wire #
Go To (Device)
GO TO
Device: 1 of 30
A=Backspace or Escape G=OK
Screen 1 of the Go To Sequence. The default is
the current device.
G = OK or Go To (Type).
The A key will exit if pressed multiple times
ϑ To call “Go To (Device)”
From the H
OME menu press key 2 (GO TO) then follow the instructions on the LCD.
Key Format:
1
2
3
4
5
6
7
8
9
Escape
A
0
OK
G