wire-bonder.pdf - 第80页
WEST•BOND MODEL 454647E SER IES INSTRUCTION MANUAL 74 ADVANCED PROGRAMMING Edit Number of Wires This enables the operator to spe cify how many wires are in a spe cific type. N OTE ! When the number of wires in a type is …

WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
73
ADVANCED PROGRAMMING
Edit Type
From this menu option, the operator can edit the number of wires in a type or change the CRITICAL BOND
of the current type.
TYPE EDIT MENU
Device 2 of 30: Type 1 of 3
4=# of wires
7=Critical bond
A=Prev menu G=Sequence
To Call “Edit Type” Menu
From the H
OME menu press 4 (EDIT), 9 (TYPE EDIT), and then press 4 (EDIT TYPE).
Key Format:
Previous
Menu
1
Go To
Device/Type
2
Home
3
Edit
# of wires
4
5
6
Critical
bond
7
8
9
Previous
Menu
A
0
Sequence
G

WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
74
ADVANCED PROGRAMMING
Edit Number of Wires
This enables the operator to specify how many wires are in a specific type.
N
OTE! When the number of wires in a type is 0, the machine will bond the
specified type indefinitely, or until it is interrupted and changed by the user.
EDIT NUMBER OF WIRES
Device 2 Type 3: Edit # of WIRES: 2
4=Key in 5=Increase
7=Prev type 8=Type 1 9=Next type
A=Prev option 0=Decrease G=Next option
To Call “Edit Number of Wires”
From the H
OME menu press 4 (EDIT), 9 (WIRE TYPE EDIT), 4 (EDIT TYPE), and then 4 (# OF WIRES)
Key Format:
Previous
Menu
1
Go To
Device/Type
2
Home
3
Key In
4
↑
Increase
5
6
Previous
type
7
Type 1
8
Next type
9
Previous
Option
A
↓
Decrease
0
Next option
G

WEST•BOND MODEL 454647E SERIES INSTRUCTION MANUAL
75
ADVANCED PROGRAMMING
Edit Critical Bond
This option allow the operator to specify the critical bond for a set type of wires, where the placement of
the second or third bond may be more critical than the first. The operator would then align the crosshairs
to the second or third bond before executing the bonding sequence.
EDIT CRITICAL BOND
Device 2 Type 1: EDIT CRITICAL BOND: 3
4=Key in 5=Next Bond
7=Prev type 8=Bond 1 9=Next type
A=Prev option 0=Prev Bond G=OK
To Call “Edit Critical Bond”
From the H
OME menu press 4 (EDIT), 9 (WIRE TYPE EDIT), 4 (EDIT TYPE), then 7 (CRITICAL BOND)
*NOTE: If the system is set in Microscope Mode (page 35) the Critical Bond will be ignored and the
operator must align to bond 1.
Key Format:
Previous
Menu
1
Go To
Device/Type
2
Home
3
Key in
4
Next bond
5
6
Previous
type
7
Bond 1
8
Next type
9
Previous
Option
A
Previous
bond
0
OK
G