BOARD DROP ALARM
If a board does not arrive under the Offload sensor when expected, at the end of
the countdown period the board drop alarm will be activated unless the Board Drop
Alarm has been “Disabled”. Refer to “Alarm Levels & Settings”.
Any dropped boards should be removed from the process tunnel. Upon restarting
the product definition, the board counts will be reset to zero.
CAUTION
WHEN REMOVING BOARDS FROM THE PROCESS TUNNEL, TAKE SUITABLE
PRECAUTIONS AGAINST THE POSSIBILITY OF INJURY FROM
THE HOT PARTS WITHIN THE HEAT ZONE.
BOARD JAM ALARM
If a space between boards does not occur under the Offload sensor when
expected, (based on the ‘board length’ and the speed of the conveyor) the Board
Jam Alarm will be activated unless the Board Jam Alarm has been set to “Off”.
QUICK COOL DOWN
Selecting the QUICK COOL DOWN symbol will start the cell
fans while the HOOD is open without heat applied to the cells.
(Select this symbol again to stop the fans)
QUICK COOL DOWN aids the cooling of the process tunnel, and is possible only
in the SHUTDOWN state.
BE CAREFUL OPENING THE HOOD, THE AIR AND THE OVEN
SURFACES ARE HOT !!

VITRONICS REFLOW SOLDERING SYSTEMS
EM 02502-G 15-Nov-00 (c) PAGE Operator’s Manual
27
RAIL CHAIN LUBRICATION
The Rail Chain Lubrication Option provides smooth operation and will extend the
life of the rail chain conveyor by periodically applying lubrication to the chain during
oven operation. The Oven MUST be running for ANY Lubrication to take place.
This Option can be used automatic or manual.
RAIL CHAIN LUBRICATION STATUS
The present status of the Rail Chain Lubrication System
can be displayed by selecting the "Lubrication" symbol
at the top of the Oven Operating Screen.
(This symbol will be displayed at the bottom of the screen during
the Lubrication Process)
The Lubrication Status dialogue box will be displayed:
Rail Lubrication System Information is displayed, including:
1) Automatic chain lubrication is enabled (or disabled).
2) Lubrication process is on (or off).
3) Number of chain cycles before the automatic lube process starts.
4) Number of lubrications before a low oil warning is displayed.

VITRONICS REFLOW SOLDERING SYSTEMS
EM 02502-G 15-Nov-00 (c) PAGE Operator’s Manual
28
RAIL CHAIN LUBRICATION
The automatic lubrication starts when the chain has completed the number of
cycles between lubrications.
The Lubrication Icon (symbol) is displayed with the time remaining in the
Lubrication Process, as a predetermined quantity of lube oil is applied to the rail
chain.
The conveyor will start at minimum speed. 5 seconds later, lube oil will be applied
for two complete cycles of the chain.
REFILLING THE OIL RESERVOIR
The oil reservoir needs to be refilled (with the proper lubricant) when a warning
message "check chain lubricant level in tank, refill if necessary." is displayed and
the "low oil symbol" is displayed on the Graphics View Screen.
NOTE
IT IS POSSIBLE TO SELECT REFILL ONLY IF NO LUBRICATION IS
PRESENTLY IN PROCESS.