Asse mb ly In st ruct i on s 0100 5- Pac ket E di tio n 1 2 /20 07 56 3.6 .6 Mea suring th e Co mpon ent C ame ra and the P lacem ent H ead DANGER There is a high ri sk of accidents when working with t he SITEST program.…

Assembly Instructions 01005-Packet
Edition 12/2007
55
Fig. 32 Fitting a new locking plate
Æ Fit the new locking plate with both washers (1). The curvature (2) is on the underside as shown
in Fig. 32.
Æ Clean the contact surface with alcohol and attach the track scales according to the previous
allocation and measurements.
3.6.5.8 Final Test of Changeover Table Height
After fitting the adjustment sheet, check that the nozzle 905 does not collide with the locking
plate. 3
Æ Carefully move the gantry (with the nozzle 905 in placement position) along the entire locking
plate area. The nozzle must not touch it.
Æ Adjust the locking plate fixtures if necessary.
1
1
2

Assembly Instructions 01005-Packet
Edition 12/2007
56
3.6.6 Measuring the Component Camera and the Placement Head
DANGER
There is a high risk of accidents when working with the SITEST program.
SITEST may only be started by authorized persons, who have been specially trained by SIPLACE !
En
sure that all Component changeover tables (Component trolleys) are moved into the machine,
properly docked into place and configured (set up). 3
Æ Start the SITEST software.
Æ Configure the new camera in SITEST.
Æ Go to the main view and open the "Machine configuration" function.
Æ Choose the tab for the appropriate gantry (e.g. "Gantry 1) and activate the component camera
"C&P (Type 38) 16x16 digital".
Fig. 33 SITEST "configuring the Component camera"
Æ Perform a reboot and restart SITEST.
Æ Insert the new sleeves (refer to „Inserting the Sleeve SP12 Comp. / 270 Degree Partition
[03054107-xx]“ auf Seite 48).
Æ Perform a complete reference run for the machine.

Assembly Instructions 01005-Packet
Edition 12/2007
57
Æ Select the function "C&P Heads".
Æ Select the "Head and Component Camera" function for the relevant placement head.
Fig. 34 SITEST "head and component camera"
Æ Activate the "Calibrate head" function. A complete calibration of the head and the component
camera will be executed.
Æ Calibrate the machine zero point.
3.6.7 MFU with Retrofitted Machine using the 01005 Travel Profile 33/34
Æ
Check that the 3 sleeves for 01005 placement have been used at the measured positions.
Where necessary, insert the sleeves for 01005 placement. See also section 3.6.4 on page -
48.
Æ Make sure that the travel profiles in the CS description of the "Ceram Pad" component are set
according to the description in section 3.7.2.2 on page - 62.
Æ Perform the MFU with all segments i.e. also with the standard sleeves (at the same time).