2.3 Installation
CAUTION:
Handle the new trailing cable unit carefully and enlist the help of a second per-
son if necessary. Make sure that the flat ribbon cable and the compressed air
hoses are not rubbed against any parts or kinked. Look out for sharp edges.
1. Complete trailing cable unit
2. Pressure plates on the power track chain
3. Pressure plates on the gantry
4. Pressure plate on the head mount
5. Trailing cable console
X Carefully bring the new trailing cable (1) into
the correct position. Make sure you do not
twist it.
X Temporarily fasten the ends to the machine
frame (by tying them etc.).
2
5
1
4
3
2

Replacing the Trailing Cable Unit [03039709-xx]
Installation
12 Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
X Fit the gantry interface board onto the cable
holder (4) of the new trailing cable unit.
X Fasten the trailing cable console (1) loosely
with a screw.
X Clean the trailing cable contact surface on the
machine base with a dry cloth.
X Starting from the trailing cable console (1), run
the flat ribbon cable and hoses to the relevant
connections:
Pneumatic distributor (2)
Trailing cable interface (3)
Gantry interface (4)
Gantry distributor (5)
X Reconnect to the electrical system. Observe
the correct connector assignment.
X Shorten the compressed air hoses to the opti-
mum length, making sure that they are not too
short or long. They must engage firmly but
should not buckle.
X Reconnect to the compressed air supply. Ob-
serve the correct connector assignment.
X Fasten the pressure plates (6) loosely to the
machine base.
X Check that the power track chain can run alo-
ng the top of the machine base without ob-
struction. Move the Y-axis back and forth to
check this.
X Correct at the trailing cable console (1) and at
the pressure plates, where necessary.
X Fix the two pressure plates (6) and the trailing
cable console (1). Use Loctite 241 locking
paint.
X Tighten the trailing cable console (1) fastening
screws crosswise.
2
5
4
6
6
1
3

Replacing the Trailing Cable Unit [03039709-xx]
Conversion on SIPLACE HF Machines up to A 219
Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
13
2.4 Conversion on SIPLACE HF Machines up to A 219
These versions of the trailing cable unit can also be used for SIPLACE HF machines up to machine num-
ber A-219 in combination with the "retrofitting set for trailing cable" 03046248-01.
Trailing cable unit for HF machines with one gantry
– 03039706S01 analog trailing cable unit 1P
Trailing cable unit for HF machines with two gantries at uneven locations (1 and 3)
– 03039708S01 analog trailing cable unit 2P U
Trailing cable unit for HF machines with two gantries at even locations (2 and 4)
– 03039709S01 analog trailing cable unit 2P G
X Reconnect the cooling tubes to the Y-axis mo-
tor.
X Install the 3 pressure plates (1) to the gantry
and the head mount (2).
X You will need to replace the cable supports on
SIPLACE HF machines up to machine number
MA219. See also Section 2.4 Conversion on
SIPLACE HF Machines up to A 219 [J 13].
X Fit the head board (3). Make sure you do not
lose the contact disks or spacer bolts.
X Plug in all connections/terminals. Observe the
correct connector assignment.
X Fasten new cable ties at the original points.
X Replace all cover plates.
5
1
3
2
The new pressure plate is no longer fastened to
the existing cable supports. Therefore, the old ca-
ble supports (1) need to be replaced.
X Replace the old cable supports (1) with the
new cable supports (2) from the retrofitting set.
The new cable supports have 4 drillings (3) to