Replacing the Trailing Cable Unit [03039709-xx] Conversion on SIPLACE HF Machines up to A 219 Service Manual Exchange of the trailing cable SIPLACE HF and X-Series 13 2.4 Conversion on SIPLACE HF Machines up to A 219 The…

Replacing the Trailing Cable Unit [03039709-xx]
Installation
12 Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
X Fit the gantry interface board onto the cable
holder (4) of the new trailing cable unit.
X Fasten the trailing cable console (1) loosely
with a screw.
X Clean the trailing cable contact surface on the
machine base with a dry cloth.
X Starting from the trailing cable console (1), run
the flat ribbon cable and hoses to the relevant
connections:
Pneumatic distributor (2)
Trailing cable interface (3)
Gantry interface (4)
Gantry distributor (5)
X Reconnect to the electrical system. Observe
the correct connector assignment.
X Shorten the compressed air hoses to the opti-
mum length, making sure that they are not too
short or long. They must engage firmly but
should not buckle.
X Reconnect to the compressed air supply. Ob-
serve the correct connector assignment.
X Fasten the pressure plates (6) loosely to the
machine base.
X Check that the power track chain can run alo-
ng the top of the machine base without ob-
struction. Move the Y-axis back and forth to
check this.
X Correct at the trailing cable console (1) and at
the pressure plates, where necessary.
X Fix the two pressure plates (6) and the trailing
cable console (1). Use Loctite 241 locking
paint.
X Tighten the trailing cable console (1) fastening
screws crosswise.
2
5
4
6
6
1
3

Replacing the Trailing Cable Unit [03039709-xx]
Conversion on SIPLACE HF Machines up to A 219
Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
13
2.4 Conversion on SIPLACE HF Machines up to A 219
These versions of the trailing cable unit can also be used for SIPLACE HF machines up to machine num-
ber A-219 in combination with the "retrofitting set for trailing cable" 03046248-01.
Trailing cable unit for HF machines with one gantry
– 03039706S01 analog trailing cable unit 1P
Trailing cable unit for HF machines with two gantries at uneven locations (1 and 3)
– 03039708S01 analog trailing cable unit 2P U
Trailing cable unit for HF machines with two gantries at even locations (2 and 4)
– 03039709S01 analog trailing cable unit 2P G
X Reconnect the cooling tubes to the Y-axis mo-
tor.
X Install the 3 pressure plates (1) to the gantry
and the head mount (2).
X You will need to replace the cable supports on
SIPLACE HF machines up to machine number
MA219. See also Section 2.4 Conversion on
SIPLACE HF Machines up to A 219 [J 13].
X Fit the head board (3). Make sure you do not
lose the contact disks or spacer bolts.
X Plug in all connections/terminals. Observe the
correct connector assignment.
X Fasten new cable ties at the original points.
X Replace all cover plates.
5
1
3
2
The new pressure plate is no longer fastened to
the existing cable supports. Therefore, the old ca-
ble supports (1) need to be replaced.
X Replace the old cable supports (1) with the
new cable supports (2) from the retrofitting set.
The new cable supports have 4 drillings (3) to
fix the new pressure plate.

Replacing the Trailing Cable Unit [03039709-xx]
Conversion on SIPLACE HF Machines up to A 219
14 Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
X Fit the pressure plate for the new trailing cable
unit onto the new cable supports, with the 4
M3x35 screws from the retrofitting set.
X If the pressure plate does not fit into the exi-
sting drillings on the gantry, loosen the pressu-
re plate clamp and adjust it.
X Tighten the clamp again and fit the pressure
plate onto the gantry drillings.