00195170-01 SA trailing cable - 第28页

Replacing the Trailing Cable Unit (IGUS) on X- Series Machines from B-079 [03 021065-xx] onwards Disassembly 28 Service Manual Exchange of the trai ling cable SIPLACE HF and X-Series X Disconnect the flat ribbon cable (1…

100%1 / 34
Replacing the Trailing Cable Unit (IGUS) on X-Series Machines from B-079
[03021065-xx] onwards
Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
27
CAUTION: Before Cutting the Compressed Air Hoses
X Mark the order in which the compressed air hoses are arranged (from 1 to 7
– from inside to outside). This ensures that you connect the correct hoses to
one another again afterwards.
X Make sure that the compressed air hoses do not fall into the machine base
when they are cut. Secure them if necessary.
X Make sure that the correct gauge is used (for the appropriate gantries) and
that the hoses are not cut too short.
X Loosen the screws fastening the mounting
block (3) of the trailing cable.
X If you are using the optional „vacuum pump“,
disconnect the compressed air hoses (2) and
follow the instructions in the
vacuum pump
retrofitting instructions
[00195089-01].
X Secure the end of the trailing cable (with cable
ties) in the machine to prevent it hanging loo-
sely and damaging other machine compon-
ents.
Replacing the Trailing Cable Unit (IGUS) on X-Series Machines from B-079 [03021065-xx] onwards
Disassembly
28 Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
X Disconnect the flat ribbon cable (1) from the
head board (2).
X Disconnect the camera cable (3) from the
head board (2).
X Loosen the screws fastening the X-axis trailing
cable clamp (4) and the two clamps (5) on the
back of the gantry.
NOTE: The clamp will remain in pla-
ce
X Only the fastening screws will be
loosened. The clamps for the flat
ribbon cable will remain in place.
X Take care not to lose the contact di-
scs and the spacer bolts and also
mark where they were fitted. These
will need to be correctly replaced
later.
X Disconnect the hoses from the pneumatic dis-
tributor (7).
WARNING: Risk of injury to the
hands
X Use the hose unlocking device to
remove the hose [03047090-xx].
X Loosen the 4 screws (6) fastening the trailing
cable console and carefully remove the com-
plete trailing cable unit from the machine. The
fastening screws are secured with Loctite.
Replacing the Trailing Cable Unit (IGUS) on X-Series Machines from B-079
[03021065-xx] onwards
Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
29
4.5 Installation
CAUTION:
Handle the new trailing cable unit ca-
refully and enlist the help of a second
person if necessary. Make sure that
the flat ribbon cable and the compres-
sed air hoses are not rubbed against
any parts or kinked. Look out for sharp
edges.
1. Complete trailing cable unit
2. Mounting block
3. Compressed air hoses (shortened to optimum
length with gauge)
4. Bracket for gantry interface
5. Gantry interface
6. Connection piece for cooling tubes to Y-axis
motor
7. Trailing cable console
8. Clamp on back of gantry
9. X trailing cable clamp
X Carefully bring the new trailing cable (1) into
the correct position. Make sure you do not
twist it.
X Temporarily fasten the ends to the machine
frame (by tying them etc.).
X Fit the gantry interface board (5) onto the hol-
der (4) of the new trailing cable.