00195170-01 SA trailing cable - 第9页

Replacing the Trailing Cable Unit [03039709-xx] Disassembly Service Manual Exchange of the trailing cable SIPLACE HF and X-Series 9 NOTE: Connect the gantry distri butor to the new trailing cable and install it in the ma…

100%1 / 34
Replacing the Trailing Cable Unit [03039709-xx]
Overview
8 Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
2.1 Overview
2.2 Disassembly
X The flat ribbon cables are run from the head
board (1), via the trailing cable console(2) and
the power track chain (3) to the gantry inter-
face (7) and trailing cable interface (4).
X The compressed air hoses are run from the
pneumatic distributor (6), via the trailing cable
console (2) and the power track chain(3) to the
gantry distributor (5) .
5
5
6
7
1
4
3
2
X Disconnect the flat ribbon cable at the trailing
cable interface (1). Take care not to lose the
brackets for the plug-and-socket connections.
They could fall out and be lost.
X Remove cable ties where necessary.
X Remove the cover on the gantry distributor (5).
X Loosen the screws fastening the gantry distri-
butor (5).
X Disconnect the hoses from the pneumatic dis-
tributor (2).
WARNING: Risk of injury to the
hands
X Use the hose unlocking device to
remove the hose [03047090-xx].
ATTENTION:
Observe the order in which the con-
nections are arranged. You will need
this sequence later, for reassembly
purposes.
3
3
4
5
1
2
Replacing the Trailing Cable Unit [03039709-xx]
Disassembly
Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
9
NOTE:
Connect the gantry distributor to the new trailing
cable and install it in the machine.
X Secure the end of the trailing cable (with cable
ties) in the machine to prevent it hanging loo-
sely and damaging other machine compon-
ents.
X Remove all necessary cable ties from the gan-
try interface (2) and unplug the flat ribbon ca-
ble.
X Disconnect the cables for the motor, proximity
switches, read head and temperature sensor
from the gantry interface (2) .
NOTE:
The gantry interface board is fitted onto the cable
holder of the new trailing cable unit.
X Pull the cooling tubes(4) off the Y motor.
X Loosen the screws fastening the pressure pla-
tes (3). to the power track chain. These screws
have been secured with locking paint.
NOTE:
Only the fastening screws will be loosened. The
clamps for the flat ribbon cable will remain in pla-
ce.
3
3
4
5
1
2
Replacing the Trailing Cable Unit [03039709-xx]
Disassembly
10 Service Manual Exchange of the trailing cable SIPLACE HF and X-Series
X Disconnect the flat ribbon cable from the head
board (1).
X Remove the pressure plate (3).
X Loosen the screws fastening the pressure pla-
te (3) to the head mount and the two screws on
the gantry (5).
NOTE:
Only the fastening screws will be loosened. The
clamps for the flat ribbon cable will remain in pla-
ce.
X Remove the head board (1). This gives you ac-
cess to the pneumatic distributor (2) below.
NOTE:
Take care not to lose the contact discs and the
spacer bolts and also mark where they were fitted.
These will need to be correctly replaced later.
X Disconnect the hoses from the pneumatic dis-
tributor (2).
WARNING: Risk of injury to the
hands
X Use the hose unlocking device to
remove the hose [03047090-xx].
TIP
Remove the hoses with a suitable pair of hose nip-
pers and dismantle the pneumatic distributor. It is
easier to disconnect the hoses when they are no
longer installed.
5
5
1
4
3
2
X Loosen the 4 screws (1) fastening the trailing
cable console (2) and carefully remove the
complete trailing cable unit from the machine.
NOTE:
The fastening screws are secured with Loctite.
X If you have dismantled the pneumatic distribu-
tor, now disconnect the hoses.
1
1
2