00198654-01_UM_Nozzle_Cleaning_Station_EN - 第44页

4 Setting up and commissioning 4.5 Setting up the nozzle cleaning station 44 User Manual SIPLACE Nozzle Cleaning Station 09/2019 Fig.29: Connections ► Plug in the compressed air supply (1) , (2) and (3) at the top left…

100%1 / 72
4 Setting up and commissioning
4.5 Setting up the nozzle cleaning station
User Manual SIPLACE Nozzle Cleaning Station 09/2019 43
Fig.26: Inserting the shaft cleaning module
Open the doors at the back of the NCS.
Remove the black cover plate where
the module is to be installed.
Insert the shaft cleaning module slightly
angled while placing the fitting pins
onto the black plastic support at the left
and right.
Fig.27: Hollow and end switch
Move the module to the front until the
fitting pins sit in the hollow(1) and the
actuator operates the end switch(2).
 NOTICE!
Ensure the proper seating of the seal-
ing below.
.
Fig.28: Positioning the module
Fix the module in position using the
screw removed with the black cover
plate.
4 Setting up and commissioning
4.5 Setting up the nozzle cleaning station
44 User Manual SIPLACE Nozzle Cleaning Station 09/2019
Fig.29: Connections
Plug in the compressed air supply(1),
(2) and (3) at the top left.
Plug in the connection (4) for the sup-
ply of the cleaning agent.
Plug in the connector to the sensor(5)
to detect the nozzle magazine and
secure it in position.
Plug in the bypass / drainage(6) at the
back of the applicator.
 CAUTION!
Prevent leakage
Make sure that all pneumatic and li-
quid connections are firmly in place.
.
4 Setting up and commissioning
4.5 Setting up the nozzle cleaning station
User Manual SIPLACE Nozzle Cleaning Station 09/2019 45
4.5.1.2 Fitting the tip cleaning module
The assembly of the tip cleaning modules can be done from the front of the NCS and requires no
additional tools.
Fig.30: NCS - tip cleaning cell
1 Tip cleaning module 2 Drainage and fixing of the module
3 Supply of the cleaning solution 4 Sensor for module recognition
Fig.31: Connection
Plug in the connection for the supply of
the cleaning agent.
 CAUTION!
Prevent fluid injection
Make sure that all connections carry-
ing liquid are firmly in place.
.