5 Tasks at the nozzle cleaning station 5.1 Filling and draining the Container User Manual SIPLACE Nozzle Cleaning Station 09/2019 47 5 Tasks at the nozzle cleaning station 5.1 Filling and draining the Container The clean…

100%1 / 72
4 Setting up and commissioning
4.5 Setting up the nozzle cleaning station
46 User Manual SIPLACE Nozzle Cleaning Station 09/2019
Fig.32: O-rings
Dampen the o-ring at the left and right
with water.
Position both connector over the drain
holes in the base plate.
Fig.33: Module on base plate
Turn the module and push it firmly in
place so the underside sits plane on
the base plate.
5 Tasks at the nozzle cleaning station
5.1 Filling and draining the Container
User Manual SIPLACE Nozzle Cleaning Station 09/2019 47
5 Tasks at the nozzle cleaning station
5.1 Filling and draining the Container
The cleaning of SIPLACE ceramic nozzles requires 3 different liquids and runs in 4 steps.
Nozzle tip cleaning (KG15+ from ASM)
Nozzle tip rinsing (Demi water)
Nozzle shaft cleaning (Vigon SC)
Nozzle drying (compressed air)
All liquids must be replaced frequently as they saturate more and more over the time used. The
cycle time to exchange the liquids depends heavily on the surrounding conditions and the degree
of pollution. In average they should be exchanged after 1000 – 1500cycles.
Liquid Qty Part number
NCS additive KG15 nozzle tip cleaner 5l 03172986-xx
Zestron Vigon SC different Local distributor
Demineralized water different Local supplier
5.1.1 Container for demineralized water
The demineralized water containers are in the lower part at the back of the NCS.
DANGER
Risk of damage / life!
Before changing the cleaning modules, stop the machine operation and disconnect it from
the power supply with the main power switch.
CAUTION
Hazardous material
The demi in the wastewater container can contain residues of KG15+, solder paste and
metal particles from components.
Observe the applicable safety data sheet and consider existing local regulation for dis-
posing of hazardous materials.
NOTICE
Level control
The level in the demi container is sensor controlled. If the level drops below the sensor the
NCS stops operation.
Make sure that there is enough liquid in the container.
5 Tasks at the nozzle cleaning station
5.1 Filling and draining the Container
48 User Manual SIPLACE Nozzle Cleaning Station 09/2019
Fig.34: NCS - container located at the back
1 Screw cap wastewater container 2 Wastewater container (30l)
3 Screw cap demi container 4 Demi container
5 Drain hose for front container
Filling the demi container
Remove the back cover.
Open the screw cap at the demi container (1).
Remove the container (2).
Remove any liquid residues.
Fill the container (2) with demi and put it back to the NCS.
Connect the demi container (1).
Close the back cover.
Draining the demi container
Remove the back cover.
Open the Screw cap to the wastewater container (3).
Remove the container (4) and clean up any liquid residues.
Empty the container (4) and put it back to the NCS.
Connect the wastewater container (1).
Close the back cover.