Retrofitting Instructions Flux Dispenser (Optional) on SIPLACE 80F
4
Edition 08/98
Page
7
from
14
3.3 Installing the Flux Dispenser Head
3.3.1 Installing the Flux Dispenser Head
• Fasten the dispenser head to the camera holder with 4 M5 x 12 socket head cap screws.
• Exchange component illumination board Y0021 for component illumination board, flux, Y1033.
• Remove the cover plate under the pump housing.
• Connect X1 of the conversion board, flux, to X8 of the component illumination board, flux. Use the cable
“Flux monitoring, 00323903-01.
• Connect X95 of the flux pump to X7 of component illumination board, flux. Use the cable “Control, flux
pump”, 00323902-01.
• Re-install the cover plate.
• Remove the U-shaped machine casing for conversion PC board C0003.
• Plug the cable “V24 Flux” onto unused board slot X26, and run the other end through the machine base
to the control unit.
• Slip the cable onto connector X4 of the communication module.
• Re-install the U-shaped casing for the conversion PC board.

Flux Dispenser (Optional) on SIPLACE 80F
4
Retrofitting Instructions
Edition 08/98
Page
8
from 14
3.3.2 Tubing for Flux Dispenser Head
• Run the long branch of the compressed air hose through the 2 holes in flux dispenser head
• Loosen the clamping force on the pipette tube by backing the centering pipette out about 3 to 4
revolutions.
• Insert the pipette tube into the dosing cylinder from the top.
• Fasten the pipette tube in place by retightening the centering pipette. The pipette tube should project
about 3 mm.
• Run the tubing for flux dispenser head as shown in Fig. 1.
Note
Run the tubes in such a manner that they cannot drag on the hood of the machine.
Figure 1 Flux Dispenser Head
− Key to Fig. 1
Centering pipette ô Clamping piece
í Cylinder cover ÷ Dosing hose with pipette tube
û Valve and syringe ø Cylinder

Retrofitting Instructions Flux Dispenser (Optional) on SIPLACE 80F
4
Edition 08/98
Page
9
from
14
3.3.3 Installing the Syringe on the Flux Dispenser Head
• Insert the dosing piston into the syringe.
• Screw the syringe into the valve with the retaining nut.
• Pull the dosing piston down and fasten it in place with the knurled thumb screw.
Figure 2 Syringe
− Key to Fig. 2
Knurled thumb screw ô Dosing piston
í Syringe ÷ Retaining nut
3.4 Installing the Rinsing Tank
• Remove the IC head reject box.
• Remove the reject box holder.
• Install the new reject box holder with rinsing tank holder.
• Insert a centrifugal tube into the rinsing tank holder.
• Slip the brush onto the centrifugal tube.