00198076-01_JC_PM_WF1_TX_EN - 第16页
1 WF 1 TX-Series Maintenance Remove tables (COT) and exchange nozzles 5 min 2 / 2 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n …

1 WF 1 TX-Series Maintenance Remove tables (COT) and exchange nozzles 5 min 1 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part:
W2, W35
Consumables:
www.asm-smt.com
1 Stop production and click on "block trans-
port" icon.
2 Block both lanes and click "OK" icon. 3 Click on "maintenance" icon.
4 Select "advanced production". 5 Select all "head types" CPP and CP20P. 6 Click on "prepare for manual mainten-
ance" icon.

1 WF 1 TX-Series Maintenance Remove tables (COT) and exchange nozzles 5 min 2 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part:
W2, W35
Consumables:
www.asm-smt.com
7 Press stop button. 8 Open the cover. 9 Press remove COT button.
10 Remove all COT. 11 Remove all ceramic nozzle magazines. 12 Return all maintained nozzle magazines.

2 WF 1 TX-Series Maintenance Empty and clean nozzle reject bin 2 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T2
Wear Part: Consumables:
C3
www.asm-smt.com
1 Remove the nozzle reject bin. 2 Empty the reject bin into a waste box. 3 Clean the reject bin.
4 Return the reject bin and repeat steps for
all gantries.