00193893-04 - 第77页

SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit in structions - SIPLACE HF seri es head reconfiguration kits 05/2006 Edition 77 : Set all switches to OFF be fore installing the board. 2 2 : Plug the head adapter b…

100%1 / 110
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
76
: Place the TwinHead template on the head fixing plate.
Remove any excess screws and add any necessary screws:
Fixing screws: 8x DIN 912 - M4 x 14-8.8, item no.: 00095021-01xx,
Sealing screws: 5x DIN 913 - M4 x 6-ST, item no.: 00309422-01-xx.
Screws in the wrong place could affect the flow of cooling air to the X-axis motor.
2
2
2
Always use the standard tool.
Make sure that the screws are of the right length. The lengths are different for C&P heads and the
TwinHead.
If you use the wrong screws, there is a risk of damaging the thread on the head plate.
Tightening torque for the fixing screws: 2.7 Nm. 2
2
2
Seal for
head plate
Fixing
for module 2
Fixing
for module 1
SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
77
: Set all switches to OFF before installing the board.
2
2
: Plug the head adapter board from below into the head interface board (03000902-xx) and
screw in place with the four screws.
2
2
2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
78
: Fit the strain relief to the new board (the pushbutton must be on the outside of the gantry).
2
2
: Plug in the new cables as follows:
the shorter cables on the inner (rear) module, the longer cables on the outer module,the very
short cables at the bottom, the longer cables on top.
2
2
2
2
2
2
2