2 Retrofit instructions - SIPLACE HF series head re confi guration kits SIPLACE HF Series Head Reconfiguration Kits 05/2006 Edition 92 : Plug the cables and the compressed air hose into the C&P head nozzle changer . …

SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
91
: Fit the nozzle changer extension on the inside of the placement machine.
2
2
: Remove the sensor for the TwinHead reject bin and wire it to the new reject bin for the C&P
head.
: Attach the sensor to the mount for the new reject bin.
2
2
: Insert the reject bin(s) for the C&P head.
2
2
2
Refit the sensor
Remove the sensor

2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
92
: Plug the cables and the compressed air hose into the C&P head nozzle changer.
2
2
: Insert the new C&P head nozzle changers and fix each in place with four screws.
2
2
With the C&P 12 placement head, an optional third nozzle changer may be fitted on the opposite
feeder area. It is installed and connected up in the same way. 2
2
2
2
2
2
Cable
Compressed air connector
C&P 12 nozzle changer
C&P 6 nozzle changer

SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
93
2.5.4 Replacing the placement head
2
Wear an ESD armband for the whole time you are working on the placement head and servos. 2
2
2
The conversion is easiest to carry out from locations 2 and 4. 2
2
2
: Disconnect the exhaust air hoses.
2
2
: Detach these hoses and the blanking plug.
2
Blanking plug
Hoses