SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit in structions - SIPLACE HF seri es head reconfiguration kits 05/2006 Edition 97 : Plug the 03019066-xx DLM2 hea d adapter from below into the head inte rface board, …

2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
96
: Place the DLM head template on the head fixing plate.
Remove any excess screws and add any necessary screws:
Fixing screws: 4x DIN 912 - M4 x 18-8.8, item no.: 00095023-01xx,
Sealing screws: 9x DIN 913 - M4 x 6-ST, item no.: 00309422-01-xx.
Screws in the wrong place could affect the flow of cooling air to the X-axis motor.
2
2
2
Always use the standard tool.
Make sure that the screws are of the right length. The lengths are different for C&P heads and the
TwinHead.
If you use the wrong screws, there is a risk of damaging the thread on the head plate.
Tightening torque for the fixing screws: 2.7 Nm. 2
. 2
Seal for
head plate
Fixing
C&P 6/12

SIPLACE HF Series Head Reconfiguration Kits 2 Retrofit instructions - SIPLACE HF series head reconfiguration kits
05/2006 Edition
97
: Plug the 03019066-xx DLM2 head adapter from below into the head interface board, and
screw in place.
: Plug the 00344488-xx modular SM board onto the DLM2 head adapter and fix in place with the
appropriate screws.
2
8 bit variant 2
: Then plug in the 80C515 HF processor board (03013014-xx) and screw in place.
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2 Retrofit instructions - SIPLACE HF series head reconfiguration kits SIPLACE HF Series Head Reconfiguration Kits
05/2006 Edition
98
: Set the DIP switch on the processor board according to the information below.
2
Abb. 2.5.1 Table: DIP switch
2
2
2
2
2
2
2
Standard OFF OFF OFF OFF ON ON CAN_address
Switch-
setting
1
CAN_R120
2
EPROM_WE
3
Test_Mode
4
CAN_ERR_
SWITCH
5
Jumper 5
6
Jumper 6
7
CAN_ID1
8
CAN_ID0
ON X
See
above
See above
OFF X X X X X
See
above
See above
DIP Schalter
ON
78123456
Gantries Switch 7 Switch 8
Gantry 1 ON ON
Gantry 2 ON OFF
Gantry 3 OFF ON
Gantry 4 OFF OFF