00195642-01_IM-SetupCenter-3.0_EN - 第45页
Installation Optional: Docking Station Hardware Installation Installation Manual SIPLACE Setup Center V3.0 45 Connection Example 2 Connection Example 1 and 2 Compressed Air and Power Supplies NOTE: The integrated termina…

Installation
Hardware Installation Optional: Docking Station
44 Installation Manual SIPLACE Setup Center V3.0
See the connection scenarios below for CAN Bus cable connection.
CAN Bus Cable Connection Examples
Connection Example 1
Legend:
1. CAN Bus Address Switch
2. CAN Connection
NOTE:
The first and the last terminating resistor must always be switched ON and the other switched
OFF independent of the number of docking stations.
NOTE:
The integrated terminal resistor can be connected and simultaneously connects / disconnects
the outgoing bus cable when deactivating / activating. This allows an easy start up of the bus
system one segment at a time.

Installation
Optional: Docking Station Hardware Installation
Installation Manual SIPLACE Setup Center V3.0
45
Connection Example 2
Connection Example 1 and 2
Compressed Air and Power Supplies
NOTE:
The integrated terminal resistor can be connected and simultaneously connects / disconnects
the outgoing bus cable when deactivating / activating. This allows an easy start up of the bus
system one segment at a time.
NOTE:
The compressed air and power connections can be found on the back of the docking station.

Installation
Hardware Installation Optional: Docking Station
46 Installation Manual SIPLACE Setup Center V3.0
X Connect to the compressed air supply.
X Set the pressure reducer on the pneumatic connection (external) to 5.5 bar.
X Switch off the power supply and connect the CAN Bus cable to the device.
X Switch on the power supply.
X You will find a control lamp on the front of the device. This will shine when power is correctly supplied
to the device.
6.2.4.5 Firmware download for docking station
X Setup Center can update the firmware of your docking station.
To learn how to update the firmware of your docking station, please refer to the chapter "Docking
Station Firmware Download" in the Online Help Setup Center 3.0.
DANGER:
Never cover the air discharge opening in the integrated fan and the ventilation slits on the side
of the device!
Covering these could lead to overheating and destruction of the power pack.
DANGER:
Make sure that nobody is using the connected component trolley when you switch the power on.
6-12: Docking station: compressed air and power supplies
Legend:
1. Compressed Air Connection
2. Power Connection
3. Set Compressed Air