00195642-01_IM-SetupCenter-3.0_EN - 第71页

Installation DATALOGIC Scanner Configuration Steps to perform after Installation Installation Manual SIPLACE Setup Center V3.0 71 X Choose the right COM port at which the cradle is conn ected. This was already found out …

100%1 / 94
Installation
Steps to perform after Installation DATALOGIC Scanner Configuration
70 Installation Manual SIPLACE Setup Center V3.0
X Select "firmware upgrade" from the menu "Tools".
X Select "load firmware file" in the dialog box.
X Open the folder where the firmware version 1.1.0-00_ b00 for the Datalogic Dragon M131 is stored
(standard path "C:\Program Files\Datalogic\Aladdin\resource\ConfigRepository\DRAGON
M131_1.1.0 00_ b00").
Installation
DATALOGIC Scanner Configuration Steps to perform after Installation
Installation Manual SIPLACE Setup Center V3.0
71
X Choose the right COM port at which the cradle is connected. This was already found out
automatically at the beginning.
X Activate the scanner by pushing the laser trigger.
X Then select "firmware upgrade" to start the transfer of the new firmware version to the scanner.
X Exit the "Datalogic Aladdin", if the transfer is completed.
6.4.3.3 Reconnection of the PowerScan scanner to the cradle OM3010
If after wrong connection to the cradle no communication could be established, the following
configuration steps are necessary. Please scan the following barcodes in the order they are printed:
The standard configuration of the scanner is restored.
X Sann the barcode "0" four times.
Installation
Steps to perform after Installation DATALOGIC Scanner Configuration
72 Installation Manual SIPLACE Setup Center V3.0
The scanner must have an address (temporary "0000"), so that it can get connected to the cradle. This
address will be changed / set again later by Setup Center with the automatic configuration.
In order to configure the cradle a scanner needs to be bound to the cradle with the barcode "Bind".
X Scan the barcode "Bind" now.
X If the green LED of the scanner blinks, put the scanner into the cradle.
X The green LED is now switched off and the scanner is already registered on the cradle. This can be
set up now with the following barcodes.
X Scan "Restore OM-30X0 Default" now to restore the standard configuration of the cradle.
X Scan "RS232 Standard" to fix the interface to be used on the cradle.