Fitting the Gantry Installing the Gantry Fitting the Short End Position Buffe r 96 Gantry Modularity Portalmodularität 3.4.1 Fitting the Short End Position Buffer The short end position buffer m ust be fitted in SIPLACE …

100%1 / 120
Fitting the Gantry
Transportation Locks and Tilt Guard Installing the Gantry
Gantry Modularity Portalmodularität 95
Remove the tilt guard and move in the gantry
The docking hooks are hooked into place on the left (1)
and right (2) sides.
The gantry carrier with the gantry is now fixed reliably
onto the machine.
Open the tilt guard (1).
Push the gantry (2) into the machine so that both
sides of the gantry rest on the two linear guides.
Move the gantry lift with the gantry carrier out of the
location.
Move the gantry (2) into the machine so that the trail-
ing cable (1) can be pulled underneath, through the
gantry.
Fitting the Gantry
Installing the Gantry Fitting the Short End Position Buffer
96 Gantry Modularity Portalmodularität
3.4.1 Fitting the Short End Position Buffer
The short end position buffer must be fitted in SIPLACE SX machines with two gantries. This buffer
needs to be removed and replaced with the long end position buffer in SIPLACE SX machines with one
gantry at location 1.
Carefully place the flat ribbon cable (1) and the pneu-
matic connections (2) over the gantry.
Remove the black plastic foil. A cable tie fixes the
black plastic foil to the trailing cable (1).
Fit the end position buffer (2) to the left side.
Fit the end position buffer (3) to the right side. The
safety switch (4) for the buffer monitoring function
must engage in the Schmersal switch.
Tighten the fastening screws (1) for both buffers.
Fitting the Gantry
Fitting the Short End Position Buffer Connecting the Trailing Cable
Gantry Modularity Portalmodularität 97
3.5 Connecting the Trailing Cable
Remove the cover (1) over the gantry interface. To do
this, loosen the two fastening screws on the right side
and carefully open the bottom left pushbutton.
Fit the trailing cable holder (1) from below, to the gan-
try distributor holder. See the following section.
Carefully place the flat ribbon cable and the pneumat-
ic hoses to one side (2).
Make sure you do not damage the cables and hoses.
Take care that the alignment is correct and that all ca-
bles and hoses are run above one another and even-
ly.
NOTICE!
When fitting the trailing cable, make sure that the heat-
shrinkable sleeve (1) protects the flat ribbon cable under
the Y sensor module holder.