00198596-02_JC_3M_C - 第49页
14 3-monthly C&P20 P2/M3 Head Finishing the head maintenance 1 min 1 / 2 Refer to safety instructions in user manual before commencing Maintenance NOTICE! ESD guidelines are to be followed Tool: T7, T8, T9, T21, T42,…

www.asm-smt.com

14 3-monthly C&P20 P2/M3 Head Finishing the head maintenance 1 min 1 / 2
Refer to safety instructions in user manual before commencing Maintenance
NOTICE! ESD guidelines are to be followed Tool:
T7, T8, T9, T21, T42, T53, T94
Wear Part:
W25, W59
Consumables:
C3, C5, C21
www.asm-smt.com
1 Put the headstand flat on the table. 2 Remove the maintenance label 3 Clean the area of the label
4 Attach the label with the actual date 5 Mount the calibration nozzles to each
segment.
6 Remove the head from the headstand by
loosing the 2 screws.

14 3-monthly C&P20 P2/M3 Head Finishing the head maintenance 1 min 2 / 2
Refer to safety instructions in user manual before commencing Maintenance
NOTICE! ESD guidelines are to be followed Tool:
T7, T8, T9, T21, T42, T53, T94
Wear Part:
W25, W59
Consumables:
C3, C5, C21
www.asm-smt.com
7 Place the head into the transport con-
tainer.