00900068-02_SM_ASM_ProcessLens_EN - 第46页

ASM Proces sLens Single - l ane 03/2020 Edit ion 46 3.16 Changing the motor for the widt h adjustment Re quirements: ● Machine is switche d off . ● Lifting tab le plate is dism antled . Ke y: 1) Tens ion ring 2) Sc re w …

100%1 / 92
ASM ProcessLens Single-lane 03/2020 Edition
45
Figure 3-50: Diagnostic page
1. Open the Diagnostic page.
2. Go to the tab "System Test"
3. Click on the button "Track zero point calibration"
4. A message will indicate that the calibration was successful.
5. Go to the tab Unit function.
6. Proceed to the conveyer section and press the buttons "Lift Home", "Lift up" and "Lift down" to
check the function of the lifting table.
7. On screen messages will confirm the successful function test of the lifting table.
8. If the conveyor system does not move or any fault message occurs, the conveyor system
needs to be adjusted.
ASM ProcessLens Single-lane 03/2020 Edition
46
3.16 Changing the motor for the width adjustment
Requirements:
Machine is switched off.
Lifting table plate is dismantled.
Key:
1) Tension ring
2) Screw A
3) Screw B (2 x)
4) Width adjustment belt
5) Motor
Figure 3-51: Motor of the width adjustment
1. Unscrew the screw A (2) to loosen the tension ring (1).
2. Unscrew the screw B (2 x) using an Allen key size 3.0
Key:
1) Connectors for the width
adjustment motor
2) TSP400
Figure 3-52: TSP400
3. Disconnect the connectors of the TSP400.
4. Replace the motor.
5. Connect the connectors to the TSP400.
6. Tighten the screws.
7. Go to section 3.16.1 Check system test to check the function.
ASM ProcessLens Single-lane 03/2020 Edition
47
Installation
Follow the removal instructions in reverse order for installation.
3.16.1 Check system test
Requirement:
Machine is switched on.
Figure 3-53: Diagnostic page
1. Open the Diagnostic page.
2. Go to the tab "System Test"
3. Click on the button "Track zero point calibration"
4. A message will indicate that the calibration was successful.
5. Go to the tab Unit function.
6. Proceed to the conveyer section and press the buttons "Track Home".
7. On screen messages will confirm the successful function test.
8. If the conveyor system does not move or any fault message occurs, the conveyor system
needs to be adjusted.