4 Machine - Calibrations
The calibration sequence and tests´ objectives of the ProcessLens are listed below.
Step Procedure Functional check Tooling
1.
Verify the 2D and 3D optical focal planes
Grating check
Scale
Rotation
Zero reference
Resolution specification: 3.716 +/- 1%
(3.6788 to 3.7532) um/pixel
Camera Rotational specification: not
exceeding ± 0.5°
2D/3D Calibration tool
2.
Capture the zero position of the machine
None
3.
Positional accuracy check of stop position
after a move
Objective: Delta offset from target 10µm
One Point Dynamic jig
4.
XY mapping
Gantry alignment
Objective: Delta of Gantry to fiducials´
positions 20µm
Note:
1. Left to Right and Right to Left Mapping
procedures are same.
Left-Right Transport - input mapping
plate from left
Right-Left Transport - input mapping
plate from right
2. ONLY perform when necessary
SIPLACE Mapping
plate Version 5
Coaxial light
5.
Same as in Step 1
2D/3D Calibration tool
6.
Height calibration Objective: Cg and Cgk >
1.33 for all the 9 areas of the FOV
Certified height
ceramic target
ASM ProcessLens Single-lane 03/2020 Edition
57
Before starting the calibration procedures, reset machine kinematics to default values.
4.1 Calibrations - 2D and 3D Calibration
The objectives are:
Z axis Calibration: Auto Focus
Calibrate camera to gantry XY rotation
2D Calibration
3D Calibration
One side of the calibration tool is for 3 dimensional and the other 2 dimensional. The 2D target is
wired with a lighting module.
2D and 3D Calibration tool
1. Check the calibration tool. Clean with a lint free cloth if necessary.
2.
Coil the 2D light cable into the cavity as shown.
1) 2D back light cable and
connector.
3D Calibration Target 2D Calibration Target