ASM Proces sLens Single - l ane 03/2020 Edit ion 65 4.3 Cali brations - One Point D y na mic Test The One Po int D ynamic Test test the accur acy of th e stopping positio n after a gantr y move. A comm and is given t o m…

100%1 / 92
ASM ProcessLens Single-lane 03/2020 Edition
64
Step 2
1.
Set the 2D H_Ring light to about
15, all other lighting values r
emain
at 0. The fiducial comes into view.
2.
Click on the centre of the fiducial
to centre the camera´s FOV to the
fiducial´s centre.
Step 3
1.
Click on Focus icon.
2.
At Utility > Machine Zero Point
Calibration, click Continue..
The machine zeroes onto the
fiducial.
3.
Click OK.
ASM ProcessLens Single-lane 03/2020 Edition
65
4.3 Calibrations - One Point Dynamic Test
The One Point Dynamic Test test the accuracy of the stopping position after a gantry move. A
command is given to move the camera away from the target, then return to the target and the
variation between the theoretical and actual stop position as measured by the camera is analysed.
The process is repeated 50 times.
Step 1
1. Remove the cover (1) by loosing the 4 screws.
2. Check the glass target (2) for scratches or damage. Clean with lint free cloth & IPA if
necessary.
ASM ProcessLens Single-lane 03/2020 Edition
66
Step 2
1.
Go to Inspection Page.
2.
Click Adjust Conveyor.
3.
Set the following;
Thickness, 4mm.
Width, 250mm
4.
Click Set.
5.
Click Diagnostic Page.
6.
At Miscellaneous, click Open
Door.
7.
Push the gantry to the back
CAUTION
Do not push on the camera module. Remove all supporting pins.