Step 5
1.
Click System Test.
2.
At Utility, select One Point
Dynamic Test.
3.
At the Lighting Box menu, set
Back light to 25 and all other
lighting values to 0.
4.
Click Continue.
Step 6
1.
Click on Jogging.
2.
Click on the directional arrows to
jog the camera over to the target
until the square target comes into
view.
3.
Click the centre of the square
target. The camera centres the
FOV to the square target.
Step 7
1.
Click on Focus icon.
2.
Set value between 50 ~ 60 till
image is clear.
3.
Click Continue. One Point
Dynamic test starts.
4.
Test will end estimate 65sec, click
Ok.
5.
The results are displayed.
The offset from the target should
be ≤ 10μm in both X and Y
directions. Click Ok.
ASM ProcessLens Single-lane 03/2020 Edition
69
Step 8
1.
Click on System Test.
2.
Click Lift Down.
3.
Click Open Door.
4.
Disconnect the lighting cable and
remove the target.
ASM ProcessLens Single-lane 03/2020 Edition
70
4.4 Calibrations - Table Mapping
Note
Mapping procedures for Conveyor with option Left-Right or Right-Left has the same
procedures.
Left-Right Transport - input mapping plate from left
Preparation
This procedure compares the positions of the camera across the table (work area) against a target
glass plate mapped at a higher level of accuracy and compensates for the positional differences.
1. Prepare the coaxial light assembly. The Coaxial light consists of a cable (3), a bracket (4) and
a lighting assembly (5). The glass surfaces are protected by 2 clip-on covers.
2. Remove the 2 clip-on metal protective covers (2).
3. Clean the glass surfaces of the lighting assembly if necessary with a lint free cloth.
1. The ProcessLens uses the SIPLACE SX-Series mapping plate version 5 (1). Each Mapping
glass plate has its own unique positional data map saved in a CD or in a Flash drive.
The data is in stored in a file named mp_mess.dat.
2. Open the mp_mess.dat file in the mapping CD or flash drive that comes with the mapping
plate. Compare the plate reference number (2) against the number labeled on the plate.
They should be the same.