2 PCB Camera Multicolor (Option) User Manual SIPLACE S-25 HM / HS-50 2.5 SITEST: PCB Camera Multicolor (Option) Software Version SC.502.xx 11/00 I ssue 48 Å In the conf igurat ion menu of gan try 1, ma rk the optio n &qu…

User Manual SIPLACE S-25 HM / HS-50 2 PCB Camera Multicolor (Option)
Software Version SC.502.xx 11/00 Issue 2.5 SITEST: PCB Camera Multicolor (Option)
47
6,7(673&%&DPHUD0XOWLFRORU2SWLRQ
The optional PCB camera Multicolor that is installed in place of the PCB camera with normal illu-
mination (subgantry camera) is activated/configured for HS-50 or S-25 HM at the station in the
SITEST program 502.01 or later. The operation can be performed before or after the configuration
in the station configurator of the UNIX line computer.
&RQILJXUDWLRQ
The Requirement for the configuration is that the 4 PCB cameras Multicolor are retrofitted on the
HS-50 or the both PCB cameras Multicolor are retrofitted on the S-25 HM and the safety hoods
and safety doors are closed.
All component changeover tables must be moved into the machined and docked properly.
Å Boot the machine and change over into the SITEST program.
Å Select "Settings" -> "Machine configuration".
Å On the HS-50 or S-25 HM select: "Gantry 1" -> "PCB camera" -> "Edit" (button).
Å The "Edit" window is displayed (e.g., on the HS-50):

2 PCB Camera Multicolor (Option) User Manual SIPLACE S-25 HM / HS-50
2.5 SITEST: PCB Camera Multicolor (Option) Software Version SC.502.xx 11/00 Issue
48
Å In the configuration menu of gantry 1, mark the option "Multicolor" and select "Accept" (button).
Å On HS-50: One after the other, select the remaining gantries 2, 3 and 4 as described above.
Å On SIPLACE S-25 HM: Select the PCB camera Multicolor for gantry 2 in the same manner as
described above for HS-50 and "Accept" this camera.
Å Conduct the illumination check on the PCB camera Multicolor as described below in Section
2.5.2.
Å Exit the menu "Machine configuration" by pressing "Accept".
Å Power down the machine and execute a new start so that the configuration will be accepted.
Å Next, return to the SITEST program.
Å In the main view, press the button "Total reference run".
Å Afterwards, conduct the calibration:
Whenever the PCB camera Multicolor is retrofitted, reinstalled or exchanged, all of the place-
ment heads and cameras must be calibrated - after the overall reference run - as described in
the User Manual SITEST SW V 502.xx.
LOOXPLQDWLRQ&KHFN
NOTE:
We recommend that the illumination check be performed after the PCB camera Multicolor is a ret-
rofitted, reinstalled or exchanged. By appropriately switching over the vision screen (see User
Manual SC 502.xx) it is possible to precisely check the function of the pertinent light level and, for
example, the change from full to one-half brightness.
Å In the SITEST program 502.xx select the ICON "Gantries" and then the "Gantry 1" .

User Manual SIPLACE S-25 HM / HS-50 2 PCB Camera Multicolor (Option)
Software Version SC.502.xx 11/00 Issue 2.5 SITEST: PCB Camera Multicolor (Option)
49
Å Click on the CON "PCB camera functions" .
The following screen is displayed (using S-25 HM as an example):
Å Click on the button "Illumination values for live image".
In principle, you can use this function to test whether the illumination of the PCB camera Mul-
ticolor is activated. The illumination levels "White" and "Blue" are visible; "IR" is not.