Retrofitting Instructions Splice Detection Basic Package S/F
11/2003 Edition
27
17.2 Connecting location 3 to the HUB
: Check once again that you have disconnected the station from the power supply.
: Remove the cover from the power supply unit.
17
First detach the grounding cable fixed to the inside of the cover. 17
17
17
: Remove the screw that secures the power supply unit, and pull the unit out of its drawer care-
fully.
: Loosen the 6 screws to remove the U-profile at location 3.
: Then fix the narrow end of the cable to the pilot wire, and pull it as far as the opening on the Y
axis motor (as for the connection for location 1).
: Replace the U-profile (panel) with the U-profile supplied (which has the additional opening for
the socket for connecting the splice detector).
: Fix the cable to the HUB using the 4x M3 screws provided.
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
Retrofitting Instructions Splice Detection Basic Package S/F
11/2003 Edition
28
: Pull the cable further to the opening between the power supply drawer unit and the machine
frame (Fig. 7 - 6).
17
Fig. 17 - 6 Diagram of the cable route to location 3
: Pull the cable through the machine to the opening in the servo drawer unit, and on to the hub
(as for the connection for location 1).
: Fix the new U-profile at the machine.
Retrofitting Instructions Splice Detection Basic Package S/F
11/2003 Edition
29
18 Power Supply for the HUB Unit
18
Fig. 18 - 1 Connecting the power supply for the hub
: Start at terminal block X212 (Fig. 8 - 1)
: Connect the voltage terminals as shown in Fig. 8 - 2.
: Connect the first wire (white or blue) of power supply cable to a GND terminal.
: Connect the brown wire to a +15 V terminal.
. 18
Fig. 18 - 2 Terminals for power supply
: Run the cable through the existing cable ducts to the hub.