2OM-1086-002.pdf - 第183页

1. Pattern Program Data Sheets Pattern Program Date of Preparation Comment 1 Prepared by Comment 2 (1) Operation Data P .C.B. Data P .C.B. Size X (Horizontal) ・ mm Y (V ertical) ・ mm T (Thickness) ・ mm P .C.B. Origin Off…

100%1 / 455
Section 5
Accompanying Material
0211-005 Chpter 1 5-1 Tg0583-PM-D2
1. Pattern Program Data Sheets
Pattern Program Date of Preparation
Comment 1 Prepared by
Comment 2
(1) Operation Data
P.C.B. Data
P.C.B. Size X (Horizontal) ・ mm
Y (Vertical) ・ mm
T (Thickness) ・ mm
P.C.B. Origin Offset X (Horizontal) +/- ・ mm
Y (Vertical) +/- ・ mm
Operation Mode Print/Pass
Print Area Origin +/- ・ mm
Depth +/- ・ mm
Print Data
Screen Basis Center Reference/Front Reference
/Rear Reference
Round-Way Printing ON/OFF
Frame Select 650×550/550×550/600× 550/550×650
Printing Press. [N] Front N
Rear N
Squeegee Select 270/350
Squeegee Spd. For. mm/S
Back. mm/S
Screen Distance +/- ・ mm
Separation Mode PCB Down/Squeegee Up
Separation Speed [mm/
S]
Separation Acc. [mm/
S
2
]
Separate Distance [mm]
Prntng Correction (Back) X +/- ・ mm
Y +/- ・ mm
θ +/- ・ mm
Prntng Correction (For.) X +/- ・ mm
Y +/- ・ mm
θ +/- ・ mm
Screen Offset [mm] X +/- ・ mm
Y +/- ・ mm
0211-005
Chapter 1 5-2 Tg0583-PM-D2
1. Pattern Program Data Sheets
Pattern Program Date of Preparation
Comment 1 Prepared by
Comment 2
PCB Backup
Chuck Stage Select Backup Jig/Backup Pin/Vacuum Plate
PCB Warpage Protection OFF/ON
Vacuum Release Mode Before/After
Vacuum Rel. Wait Time [sec] ・ seconds
PCB Clamp Offset Timing [sec] ・ seconds
Position [mm] +/- ・ mm
Bef.Clamp Fll Speed/10%Down/20%Down/30%Down/
Bkup Spd. 40%Down/50%Down/ 60%Down/70%Down/
80%
Down/90%Down
Aft.Clamp
Fll Speed/10%Down/20%Down/30%Down/
Bkup Spd. 40%Down/50%Down/ 60%Down/70%Down/
80%/
Down/90%Down
PCB Stopper Offset Y [mm] +/- ・ mm
PCB Cut Offset [mm] ・ mm
PEC Recognition
P.E.C. Recog. Function OFF/1PT./2PT./3PT.
Center Recognition OFF/ON
Fiducial Mark #1 X (Horizontal) ・ mm
Y (Vertical) ・ mm
Code
Fiducial Mark #2 X (Horizontal) ・ mm
Y (Vertical) ・ mm
Code
Recog Adjust Correct OFF/ON
Recog Adjust Point X (Horizontal) ・ mm
Y (Vertical) ・ mm
1. Pattern Program Data Sheets
0211-005 Chapter 1 5-3 Tg0583-PM-D2