2OM-1086-002.pdf - 第333页

10. Adjustment of P .C.B. Horizontal Clamping When a thin P .C.B. is used and the horizontal clamping force is strong, it may be warped. T o avoid this, adjust the force with the pressure re- ducing valve which is locate…

100%1 / 455
(4) Detach the filter and remove dust accumulated on the filter with an
air gun and a vacuum cleaner.
Fig. 5A37-9
(5) Set the filter such that the center hole of the filter can fit into the
flange located at the rear side of the filter cover.
Fig. 5A37-10
(6) While holding the lid, engage the clip securely such that the flange
(located at the center of the lid) can fit into the center hole of the
filter.
Fig. 5A37-11
9.2 Replacement Procedure of Blower Filter
0211-005 Chapter 3 1-31-3 Tg0583-PM-D2
Flange Section
Flange Section
10. Adjustment of P.C.B. Horizontal Clamping
When a thin P.C.B. is used and the horizontal clamping force is strong,
it may be warped. To avoid this, adjust the force with the pressure re-
ducing valve which is located at the front left (operator side) of the L
conveyor.
Fig. 5A38
• Refer to the following table for the relation between the P.C.B. thick-
ness and air pressure.
The values indicate the pressures to be applied, assuming that a
P.C.B. (Dimensions: "150 × 100 × 1.5 (t)") is used without a P.C.B.
stopper.
P.C.B. Thickness
Air Pressure 0.5 1.0 1.5 2.0 (mm)
MPa 0.12 0.2 0.3 0.3
(kgf/cm
2
) (1.2) (2.0) (3.0) (3.0)
0211-005
Chapter 3 1-32 Tg0583-PM-D2
10. Adjustment of P.C.B. Horizontal Clamping
Pressure Reducing Valve
11. Vacuum Source
• The blower-type vacuum source is provided and used for the vacuum-
type P.C.B. clamping unit and the automatic cleaning (suction type).
(1) Adjustment of Vacuum Suction Force
• The vacuum force can be adjusted with the vacuum control valve.
When the valve is turned clockwise, the suction force weakens.
Turning it counterclockwise strengthens the suction force.
Fig. 5A39
• The vacuum control valve is factory-adjusted to the condition that
it is opened (turned 9 times counterclockwise) from the "Max."
position (fully-closed position).
11. Vacuum Source
0211-005 Chapter 3 1-33 Tg0583-PM-D2
Blower Unit
Muffler
Vacuum Control Valve