CP45FVNEO Maintenance Reference (Eng, Ver3).pdf - 第83页
W eekly Inspection 3-33 Air Filter Inspection W indow Air Filter Ass’y In case of occurrence of color change or other abnorm al conditions, block the main pressurized air to the machine. Caution Shock caused by pressur…

Samsung Component Placer CP45NEO Series Maintenance Reference
3.2.6. Adjustment of Multi Cylinder Speed
Inspection
Check if the working speed of the cylinder driving the tape feeder causes any
problem in relation to the placement of the components.
Figure 3-7. Speed Control Valve
Solution
Speed Control Valve
Adjust using the speed control valve for the multi-cylinders.
3.2.7. Air Filter & Auto Drainer
Inspection
Check ff the pneumatic pressure of the machine is normal with the air pressure gauge
of the air panel on the front side of the machine. (If the air filter is clogged, the air
pressure becomes low).
Check if there is accumulated water in the air filter of the air panel on the rear side of
the machine.
Visually check through the acryl cover if the color of the filter element is change.
Visually check if the water is drained well from the drainer.
If the tube is not inserted in the drainer, insert it
Warning
If the air filter or filter element is replaced without shutting off
the air supply line, personal injury may occur. Shut off the air
supply line before replacing the air filter or filter element.
Solution
Shut off the pneumatic air supplied to the machine from the air line.
The message that the pneumatic pressure is low in the machine is displayed in the
MMI dialog box with the yellow lamp (or blue lamp) of the signal light turned on. (If
the pneumatic pressure is supplied after replacement is completed, the machine turns
to normal state).
Through the inspection window of the air filter on the air panel cover at the right side
seen from the rear of the machine, check visually if the color of the filter element in
the air filter has been changed.
3-32

Weekly Inspection
3-33
Air Filter Inspection Window
Air Filter Ass’y
In case of occurrence of color change or other abnormal conditions, block the main
pressurized air to the machine.
Caution
Shock caused by pressurization while blocking the
pressurized air may be caused. Please handle with care.
Separate the filter element bundle by turning it clockwise.

Samsung Component Placer CP45NEO Series Maintenance Reference
Separate the filter element from the filter element and replace it.
Filter Element
Assembling is done in the reverse order.
3.2.8. Control Rack Cool Fan
Inspection
Separate the front cover of the machine and check the operation of 4 cooling fans on the
control rack
Solution
After terminating the MMI and computer, Turn off the main switch on the front side
of the machine.
Main switch turn-of
f
direction
(
counterclockwise)
Remove the 4 bolts on the front side cover of the machine using the driver with (+)
shaped tip and then separate covers
3-34