Major Maintenance Maintenance Tasks for DLM 4.1.5 Final Work 48 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4 4.1.5 4 . 1 . 5 F in a l W o r k Final Wor k Fitting the front section of the head For details, refer t…

100%1 / 50
Major Maintenance
4.1.4 Performing Maintenance Tasks Maintenance Tasks for DLM
Maintenance Manual SIPLACE Placement Heads DLM3/DLM4 47
4.1.4.9
4.1.4.9 Component sensor (only DLM3)
Component sensor (only DLM3)
CAUTION
Prisms, cleaning sticks
Take care not to damage the component sensor prisms.
Make sure that you do not use the cleaning sticks soaked in oil from cleaning the sleeves.
Always use a new cleaning stick!
NOTICE!
For clarity, the diagram shows the component sensor
when removed from the machine. However, you do not
need to remove it when cleaning the component sensor.
Clean the prisms (2)on the rear side of the compo
-
nent sensor (1) with a cleaning stick soaked in etha
-
nol.
Major Maintenance
Maintenance Tasks for DLM 4.1.5 Final Work
48 Maintenance Manual SIPLACE Placement Heads DLM3/DLM4
4.1.5
4.1.5 Final Work
Final Work
Fitting the front section of the head
For details, refer to the service manual.
Insert the two O-rings into the back part of head.
Carefully insert the distributor into its seat.
Turn the placement star half a step (C&P6: 30°, C&P12: 15°), fit the front part of the head and screw
tight.
Reconnect the system to the electrical and compressed air systems.
Insert cleaned or new sleeves into the segments.
Insert cleaned or new valve plungers into the valve housing.
Fitting the Placement Head
Fit the placement head back onto the gantry. Read the service manual for your machine first.
Switch the placement machine on at the main switch.
Let the placement head take up the nozzles again.
Test placement:
The distance between the component camera and the PCB camera can be changed by separating
the front and back parts of the head.
Carry out a test placement run to test whether the placement accuracy is still guaranteed.
If the placement accuracy is not guaranteed, calibrate the segment offset 2.
CAUTION
Damage to the O-rings
The O-rings must not be seated on the distributor, otherwise they may be damaged.
Insert the O-rings into the back part of head.
acpage