S25 circuit - 第12页

SIPLACE S25 HM Det ailed C ircuit Diag rams Fold er 10/2003 U S Editi on 1 Symbols, S tructure of the T echnical Numbering System 12 1.2 S tructure of the T echnical Numbering System Document number A docu ment nu mber c…

100%1 / 146
SIPLACE S25 HM Detailed Circuit Diagrams Folder
10/2003 US Edition
1 Symbols, Structure of the Technical Numbering System 11
1.1.25 Elektromechanische Antriebe / Operating devices
1.1.26 Sicherungen und Sicherungsschalter / Fuses and fuse-switches
1.1.27 Leuchtmelder und Signaleinrichtungen / Lamps and signalling devices
1.1.28 Verstärker / Amplifiers
Nr. / No. Schaltzeichen / Symbol Beschreibung Description
07-15-01
Elektromechanischer Antrieb, allgemein
Relaisspule, allgemein
Operating device, general symbol
07-15-21
Elektromechanischer Antrieb eines
Thermorelais
Actuating device of a thermal relay
Nr. / No. Schaltzeichen / Symbol Beschreibung Description
07-21-01 Sicherung, allgemein Fuse, general symbol
Nr. / No. Schaltzeichen / Symbol Beschreibung Description
08-10-01
Lampe, allgemein
Leuchtmelder, allgemein
RD rot
YE gelb
GN grün
BU blau
WH weiß
Lamp, general symbol
Signal lamp, general symbol
RD = red
YE = yellow
GN = green
BU = blue
WH = white
08-10-02 Leuchtmelder, blinkend Signal lamp, flashing type
Nr. / No. Schaltzeichen / Symbol Beschreibung Description
10-15-01
Verstärker, allgemein
dargestellt mit Ein- und Ausgang
Anmerkung:
Die Spitze des Dreiecks muß in die
Übertragungsrichtung zeigen.
Amplifier, general symbol
Repeater, general symbol
shown with input and output
Note:
The triangle is pointed in the direc-
tion of transmission.
10-15-02
Verstärker, allgemein
dargestellt mit Ein- und Ausgang
Anmerkung:
Die Spitze des Dreiecks muß in die
Übertragungsrichtung zeigen.
Amplifier, general symbol
Repeater, general symbol
shown with input and output
Note:
The triangle is pointed in the direc-
tion of transmission.
SIPLACE S25 HM Detailed Circuit Diagrams Folder
10/2003 US Edition
1 Symbols, Structure of the Technical Numbering System 12
1.2 Structure of the Technical Numbering System
Document number
A document number consists of an item number, product status, document status, document type, language and for-
mat.
Item number
An item number consists of master number and function status
Function status (FS) = versions relevant to function
All documents pertaining to an item number have the same functions status. The versions of a product relevant to func-
tion are determined by the totality of the features describing the function and documented in the corresponding docu-
mentation.
Product status (PS)
The versions of a product not relevant to function are determined by the totality of the remaining features (no features
with relevance to function) and documented in the corresponding documentation.
Document status (DS)
The status of the contents of a technical document.
Document type
Language
Format
A Installation diagram, electrical B Construction specifications, electrical
E
Adjustment specifications, testing and inspection
instructions, setting specifications
F Movement diagram, general functions drawing
G Machine identification plate K Terminal diagram, cable diagram, wires list
L Circuit Diagram M Assembly diagram, installation diagram, mechanical
Document number
Item number
Example 00324139 - 02 01 04 Z D 3
Pattern
NNNNNNNN
-
NN NN NN
AAN
Main number S FS PS DS DT L F
Separator = - for standard part
Separator = S for service part
Function status as per SN 10370, Part 1
Product status as per SN 10370, Part 1
Document status as per SN 10370, Part 1
Document type
Language
Format
N = Numerical counting position
A = Alphabetic counting position
N Master pattern, layout, inscription P Program documentation
R Product description S Parts list
T Parts drawing U Documentation overview
V Construction specifications, mechanical W Hydraulics diagram
X Pneumatics diagram Z Assembly, mechanical
D German E English
F French I Italian
N Dutch S Spanish
X German/English Y German/Italian
0A0 1 A1
2A2 3 A3
4A4
2 Detailed circuit diagrams 13
2 Detailed circuit diagrams
NOTS25-1 EMERG.-STOP circuit, SIPLACE S-25 HM
X211 terminal strip (lefthand side)
Note:
X211/9
21
22
21
22
00321573-xx gn
00321573-xx ye
00321574-xx gn
00321574-xx ye
Protective cover
switch
switch
Protective cover
00321417-xx S1
lefthand side
righthand side
00322070-xx br
00322112-xx ye
00322112-xx gn
Component table,
WPC interface,
00321436-xx br
00321436-xx wh
00321433-xx br
00321433-xx wh
00336812-xx +24VDC
00321113-xx wh & br
push-button
push-button
00321529-xx S1
00321528-xx S1
X211/4
2
1
X211/3
2
1
X211/2
00321416-xx S1
3c 00322105-xx/X57b
4c 00322105-xx/X57b
X211/6
1a 00322064-xx/X37b
2c 00322064-xx/X37b
00321113-xx bk
00321434-xx brgn
00321434-xx whye
00321113-xx vio
4
3
X211/15
switch
Key-operated
00321113-xx rdbl
00321432-xx ye
00321432-xx gn
4
3
4
3
00321434-xx ye
00321434-xx gn
00321113-xx grpk
X211/19
X211/18
44
43
00336812-xx K3
00321528-xx S2
ON
input
00321529-xx S2
output
ON
AenderungZustand Datum
CAD-Datei : NOTS25-1.DWG
Urspr./Ers.f./Ers.d.NormName
Gepr.
Stromlaufplan/Circuit diagram
PL EA
Mat.-Nr. :
Beab. Hi
Datum 17.10.03
SMD Placement System SIPLACE S25 HM
1
2
EMERG.-STOP circuit
SIPLACE S25 HM
H2': LED ready
L2
H1': LED release
H1'
3414
24
44
58
K2'
K1'
K1'
K3'
H2'
K2'
L1
K1'
X1 X2 X3
24V AC
K3'
K2'
K3'
K1' K3'
K1'
K2'K1'
X5
K3'
X4 X6
33
13
23 43 57
66
65
H3: LED channel 1
H2+H3 = releasePOWER SUPPLY
H1: LED MAIN
UNIT
L2
X6
H2: LED channel 2
14
54
34
24
44
66
K1'
K2'
H1
L1
K3'
X1 X4
K3'K1'
H3
H2
K1
X3
K3'
K1'
24V AC
K2'K2'
K1'
K2'
K2'
X5
K3'
13 53
3323
43
65
OPTION: Cover switch, succeeding machine (00321421-xx)
Connect cable 00305817-xx to X211/13 gn - X211/14 ye
Warning: If you install the option
remove jumper X211/13 - X211/14.
remove jumper X211/11 - X211/12.
Warning: If you install the option
Connect cable 00305816-xx to X211/11 gn - X211/12 ye
OPTION: Cover switch, preceding machine (00321421-xx)
00357878-xx
push-buttonpush-button
conveyor conveyor
for machine 'ON'
software release signal
Monitoring
54
53
00336812-xx K1
00321529-xx S4
X211/8
X211/7
To power supply
Output conveyor
Input conveyor
unit
Safety protection
00336812-xx K2
Safety protection
00336812-xx K1
unit
EMERG.-STOP
EMERG.-STOP
Sh.
Sheet
SIEMENS
righthand side
righthand side
2c 00322063-xx/X3ta
1a 00322063-xx/X3ta
Component table,
lefthand side
00322069-xx br
00322069-xx lbl
X211/5
00322111-xx gn
4c 00322104-xx/X57a
3c 00322104-xx/X57a
00322111-xx ye
lefthand side
WPC interface,
00322070-xx bl
27
X211/ 25 26 28 29
conveyor
00321529-xx S2
X211/17
push-button
output
00321434-xx gr
00321434-xx pk
OPTION: X211/ 25,26,27,28,29
00321432-xx pk
WARNING: If you install the option remove
jumpers X211/ 25-26, 26-27, 27-28 and 28-29.
Connecting terminals for feeder crash sensors
conveyor
00321528-xx S2
push-button
00321432-xx gr
3
ON
4
input
ON
3
4
X211/16
00321113-xx gn
00356395-xx K3
software release signal
for machine 'ON'
Monitoring
00321113-xx bl
13
14
X211/13
X211/14
X211/11
Protective cover
switch
00303617-xx S1
Output conveyor
21
00305818-xx ye
22
X211/12
00305818-xx gn
switch
Input conveyor
00303614-xx S1
Protective cover
00305815-xx ye
22
00305815-xx gn
X211/10
21
See page 57
See page 86