S25 circuit - 第14页
2 Detailed circuit diagrams 14 NOTS25-2 EMERG .-STOP signaling ci rcuit, SIPLACE S-25 HM Off bu tton 00321432- xx vi 00321432- xx bk Key-opera ted switch 00321434- xx bk 00321434- xx vi 00321434- xx grpk rd rd 00321434- …

2 Detailed circuit diagrams 13
2 Detailed circuit diagrams
NOTS25-1 EMERG.-STOP circuit, SIPLACE S-25 HM
X211 terminal strip (lefthand side)
Note:
X211/9
21
22
21
22
00321573-xx gn
00321573-xx ye
00321574-xx gn
00321574-xx ye
Protective cover
switch
switch
Protective cover
00321417-xx S1
lefthand side
righthand side
00322070-xx br
00322112-xx ye
00322112-xx gn
Component table,
WPC interface,
00321436-xx br
00321436-xx wh
00321433-xx br
00321433-xx wh
00336812-xx +24VDC
00321113-xx wh & br
push-button
push-button
00321529-xx S1
00321528-xx S1
X211/4
2
1
X211/3
2
1
X211/2
00321416-xx S1
3c 00322105-xx/X57b
4c 00322105-xx/X57b
X211/6
1a 00322064-xx/X37b
2c 00322064-xx/X37b
00321113-xx bk
00321434-xx brgn
00321434-xx whye
00321113-xx vio
4
3
X211/15
switch
Key-operated
00321113-xx rdbl
00321432-xx ye
00321432-xx gn
4
3
4
3
00321434-xx ye
00321434-xx gn
00321113-xx grpk
X211/19
X211/18
44
43
00336812-xx K3
00321528-xx S2
ON
input
00321529-xx S2
output
ON
AenderungZustand Datum
CAD-Datei : NOTS25-1.DWG
Urspr./Ers.f./Ers.d.NormName
Gepr.
Stromlaufplan/Circuit diagram
PL EA
Mat.-Nr. :
Beab. Hi
Datum 17.10.03
SMD Placement System SIPLACE S25 HM
1
2
EMERG.-STOP circuit
SIPLACE S25 HM
H2': LED ready
L2
H1': LED release
H1'
3414
24
44
58
K2'
K1'
K1'
K3'
H2'
K2'
L1
K1'
X1 X2 X3
24V AC
K3'
K2'
K3'
K1' K3'
K1'
K2'K1'
X5
K3'
X4 X6
33
13
23 43 57
66
65
H3: LED channel 1
H2+H3 = releasePOWER SUPPLY
H1: LED MAIN
UNIT
L2
X6
H2: LED channel 2
14
54
34
24
44
66
K1'
K2'
H1
L1
K3'
X1 X4
K3'K1'
H3
H2
K1
X3
K3'
K1'
24V AC
K2'K2'
K1'
K2'
K2'
X5
K3'
13 53
3323
43
65
OPTION: Cover switch, succeeding machine (00321421-xx)
Connect cable 00305817-xx to X211/13 gn - X211/14 ye
Warning: If you install the option
remove jumper X211/13 - X211/14.
remove jumper X211/11 - X211/12.
Warning: If you install the option
Connect cable 00305816-xx to X211/11 gn - X211/12 ye
OPTION: Cover switch, preceding machine (00321421-xx)
00357878-xx
push-buttonpush-button
conveyor conveyor
for machine 'ON'
software release signal
Monitoring
54
53
00336812-xx K1
00321529-xx S4
X211/8
X211/7
To power supply
Output conveyor
Input conveyor
unit
Safety protection
00336812-xx K2
Safety protection
00336812-xx K1
unit
EMERG.-STOP
EMERG.-STOP
Sh.
Sheet
SIEMENS
righthand side
righthand side
2c 00322063-xx/X3ta
1a 00322063-xx/X3ta
Component table,
lefthand side
00322069-xx br
00322069-xx lbl
X211/5
00322111-xx gn
4c 00322104-xx/X57a
3c 00322104-xx/X57a
00322111-xx ye
lefthand side
WPC interface,
00322070-xx bl
27
X211/ 25 26 28 29
conveyor
00321529-xx S2
X211/17
push-button
output
00321434-xx gr
00321434-xx pk
OPTION: X211/ 25,26,27,28,29
00321432-xx pk
WARNING: If you install the option remove
jumpers X211/ 25-26, 26-27, 27-28 and 28-29.
Connecting terminals for feeder crash sensors
conveyor
00321528-xx S2
push-button
00321432-xx gr
3
ON
4
input
ON
3
4
X211/16
00321113-xx gn
00356395-xx K3
software release signal
for machine 'ON'
Monitoring
00321113-xx bl
13
14
X211/13
X211/14
X211/11
Protective cover
switch
00303617-xx S1
Output conveyor
21
00305818-xx ye
22
X211/12
00305818-xx gn
switch
Input conveyor
00303614-xx S1
Protective cover
00305815-xx ye
22
00305815-xx gn
X211/10
21
See page 57
See page 58
See page 58
See page 86

2 Detailed circuit diagrams 14
NOTS25-2 EMERG.-STOP signaling circuit, SIPLACE S-25 HM
Off button
00321432-xx vi
00321432-xx bk
Key-operated switch
00321434-xx bk
00321434-xx vi00321434-xx grpk
rdrd
00321434-xx rd
input conveyor
OFF
output conveyor
OFF
X2KD/6
X210/5
X2KD/5
00321528-xx S3
00321529-xx S3
X210/4
X2KD/4X2KD/2
X210/2
X210/1
X2KD + (+24VDC)
00321529-xx S200321528-xx S200321529-xx S100321528-xx S1
On buttonEMERG. STOP
00321433-xx ye 00321436-xx ye 00321433-xx grpk
00321433-xx rd00321436-xx gn00321433-xx gn
ONON
output conveyorinput conveyoroutput conveyor
push-button
input conveyor
push-button
X2KD+ (+24VDC)
X210/3
00321416-xx S1
00321417-xx S1 00321614-xx S1
14
1313
1414
13
00305818-xx wh
00305818-xx br
Cover protective
switch
output conveyor
00305817-xx br
00305817-xx wh
13
14
00303617-xx S1
13
14
00336812-xx K3
A2
A1
00336812-xx K1 00336812-xx K1
43
44
X211/21
X2KD/8 (S5 input)X2KD/1 (S5 input)
X211/22
58
57
+ 24VDC+ 24VDC
X2KB/7 (S5 input)
00336812-xx K3
22
21
+ 24VDC X2KC/8 (S5 output)
X212/4X212/4X212/4
K1
00321113-xx grbr00321113-xx whgn00321113-xx whye00321113-xx whye
00321113-xx brgn00321113-xx yebr00321113-xx whgr
Software release
Monitoring K2
Control OnControl On
Monitoring K3
Software release
X212 terminal strip (lefthand side)
X211 terminal strip (lefthand side)
X210 terminal strip (lefthand side)
Note:
13
14
Cover protective
lefthand side
switch
Cover protective
00321573-xx br
switch
righthand side
00321573-xx wh 00321574-xx wh
00321574-xx br
Cover protective
input conveyor
switch
preceding
switch
Cover protective
00305815-xx br
00305815-xx wh 00305816-xx wh
00305816-xx br
Cover protective
switch
succeeding
AenderungZustand Datum
CAD-Datei : NOTS25-2.DWG
Urspr./Ers.f./Ers.d.NormName
Gepr.
Stromlaufplan/Circuit diagram
PL EA
Mat.-Nr. :
Beab. Hi
Datum 29.01.01
SIEMENS
SMD Placement System SIPLACE S25 HM
2
2
EMERG.-STOP circuit - signaling circuit
SIPLACE S25 HM
00322111-xx pk
X210/2
5c 00322104-xx/X57a
6c 00322104-xx/X57a
5c 00322105-xx/X57b
6c 00322105-xx/X57b
00322111-xx gr
X2KD + (+24VDC)
blbk
X210/1
EMERG. STOP
00322112-xx pk
00322112-xx gr
WPC interface,WPC interface,
lefthand side righthand side
00357878-xx
Signaling circuit Signaling circuit Signaling circuit Signaling circuit
blbk blbk
monitoring of control ON and software release signal
Signaling circuits
Cover switch signaling circuit
EMERG.-STOP signaling circuits, ON/OFF push-buttons, key-operated switches
blbk
Cover open
X2KD/3 (S5 input)
machine
(Option)
00321421-xx S1 00321421-xx S1
(Option)
machine
Push-button Push-button Push-button
blbk
4
3
4
3
4
3
4
3
2
11
2
blbk blbk
(S5 input) (S5 input)
1
2
(S5 input)
Key-operated
switch
00321529-xx S4
Push-button
(S5 input)
EMERG.-STOP EMERG.-STOP
X2KD + (+24VDC)
X2KC/M (S5 output)
Sheet
Sh.
EMERGENCY-STOP signaling circuit, WPC
(S5 input)
blbk
X2KD/2
See page 86

2 Detailed circuit diagrams 15
X1-S25 X-axis, gantry 1, SIPLACE S-25 HM
30
33
32
X3aa
(Cable)
Track B
Track B29
30
Track A
Track A
33
32
X15aa
10
12
13
A
A
B
B
N
N
+15V
+5V
RI_TL
2525
2222
-15V
-15V
+15V
16
31
16
31
10
19
PGND
+24V
10
19
PGND
+24V
Gantry
00344486-xx (ac)
head distributor S23
X34aa
1
Control unit
Power supply
00356211-xx
00334520-xx
+24V
00344217-xx
(cable)
+5V
+15V
-15V
9
X-axis,
axis tracks
X1sa
GND
X1va
6
5
X8va
1
2
3
4
X3va
33
44
1
2
2
1
GND
Tacho-std
Ready
+15V
X11a
Anti-crash board
8b Enable input
Tacho std8d
Precontrol-14d
14b
Dynamic brake
DBM / 3P - 3
RSE
T
ye/gn
br
GND
Track B
3
4
2
1
Track A
X-axis incremental shaft encoder
X15ac
6
9
8
7
5
gnwh
bk
rd
bl
wh
br
ye
pk
gn
Zero pulse
Signal
(Track N)
Screen
LED
GND
+5V
LED
00300911-xx
(Cable)
8
9
27
26 Track N
Track N27
26
X3ac
00321554-xx
6
5
2
3
29
8
7
6
5
+5V
-15V
+15V
+5V
+24V
X18
2
3
4
X12aa
1
+5V
00336690-xx (aa)
Gantry conversion board
Reference point
End position
X-axis enable
Tacho U
Servo unit
00343723-xx
X1
00337333-xx A15
X5va
6
X35aa
2
00357878-xx
Terminal strip
X2kf
1
(cable)
00344224-xx
wh
(lefthand side)
gantry 1
Crash signal
00321557-xx
(cable)
00344206-xx A11 (va)
13,2813,28
+5V
11
12
11
12
X10aa
24
X2ab
24
bl3 bl -
X16ac
1
2
(Cable)
00300609-xx
br
bk bk
br
+
A1
End pos. prox.
switch B1
AenderungZustand Datum
CAD-Datei : X1-S25.DWG
Urspr./Ers.f./Ers.d.NormName
Gepr.
Stromlaufplan/Circuit diagram
PL EA
Mat.-Nr. :
Beab. Hi
Datum 29.01.01
SIEMENS
SMD Placement System SIPLACE S-25 HM
1
1
X-axis, gantry 1
SIPLACE S-25 HM
3,3k
U
V
W
X13ab
4
3
2
1
10
8
7
6
5
X3ab
5
4
3
2
1
5
4
3
2
XR
1
4
3
1
2
XT
Tacho U
Tacho V
Tacho W
Tacho Mp
RSE U
RSE V
RSE W
RSE +5V
RSE GND
U
V
W
M
3~
00337065-xx
S-25
ye
br
gn
ye/gn
ye
bk
rd
wh/bk
rd
vi
wh/br
or
X motor
(cable W2)
00337065-xx
(cable W1)
00337065-xx
prox. switch 1
End position
prox. switch 1
RSE = Rotary Shaft
Encoder
Sh.
Sheet
X2sz
Machine controller M54 A1 (sa)
X1 plug assignment / servo amplifier
+15V
Tacho V
Brake out
Precontrol+
Nom-
10z
12d
10b
10d
8z
Pos. stop
Ready
Neg. stop
4b
4d
6b
2d
2b
Motor W
Power GND
18z
18b
28d,z,b
26d,z,b
20d,z,b
RLG V
GND
+15V
I²t
Force
16z
18d
16b
14z
16d
A1 (va)
00337625-xx
TBF 120 / 7 TS
X1
X-axis servo amplifier
X4va
GND1
00356211-xx
Control unit
Cable 00344240-xx
rd
nom. values
X-axis
109
Axis rear panel, gantry 1 A27 (sz)
Ready out
8
GND
Enable3
2
Ready4
5I²t
6
7
14
12
13
10
11
12
13
11 Axis GND
Servo unit backplane
V nom9
10
Tacho-std12
GND
Force13
14
X2va
00344251-xx
(Cable)
X1su
X1sz
7
8
5
6
00345015-xx
3
4
1
2
8
9
5
6
2
3
X3su
X1sm
A6 (sm)
SMP bus A32 (su)
Axis board
X22
X7sz
X2sm
X3sm
2
12
S2S1
X11e
6
1
4z Tacho Mp
Nom+
12b
12z
to X34aa
Conversion board
gantry
RLG W
Tacho W
RLG U
30d,z,b Motor V
32d,z,b Motor U
GND
+Ub
-15V
signal
4
3
2
1
8
7
10
bk
bl
Tacho U
Tacho V
Tacho W
Tacho Mp
RSE V
RSE W
RSE +5V
RSE GND
Motor U
Motor V
Motor W
Power GND
RSE U
00343908-xx
3
4
5
10,11,12,13,14
X36aa
4
3
1
2
5
32
33
32
31
X37aa
29
30
33
X10aa
X11aa
30
32
33
X12ab
32
31
29
30
33
X2ab
3,6,9,12,15
4,7,10,13,16
2,5,8,11,14
3,6,9,12,15
4,7,10,13,16
X1ab
2,5,8,11,14
(cable)
00337532-xx
00321557-xx
(cable)
+24V
00336690-xx (aa)
Gantry
X8ab
3
1
wh
br
(Cable)
00321577-xx
Limit switch 1
X-axis
00321423-xx
End pos. prox. switches
B1, B2
Y-axis
00321425-xx
Limit switch 2
X-axis
00321578-xx
(Cable)
X9ab
3
1
wh
br
Conversion board
00336689-xx (ab)
large-axis
S1 S2
conversion board
X38aa
2
6
1
8
7
(cable)
X10aa
29
30
00321557-xx
00336689-xx (ab)
Conversion board
29
(cable)
X2ab
large-axis
wh
00321558-xx
(cable)
00337541-xx
00337540-xx
(cable)
A18 (va)
X-axis (gantry 1)
+15V
-15V
2
1
X6va
X7va
1,2
3
-
0/155V
8
9
7
6
5
4
1
3
2
bl
br
ye
gr
rd
pk
gn
wh
(Gantry 1)
Axis
service
1,4,7,17,20
1,4,7,17,20
Screen
+5V
L2
+15V
+5V
1,341,34
00321547-xx
(cable)
Anti-crash board
to X11e/6
to X11e/1
1
Switch
Gantry 1
Gantry 2
See page 65
See page 86
See page 132
See page 137
See page 131
See page 74
See page 28
See page 65
See page 131
See page 132
See page 92
See page 79
See page 27
See page 73
See page 81
See page 80
See page 141