Preventive_Maintenance - 第7页
Preventive Maintenance - XPM 2 7 Revision Date: October 2004 Procedure 3: PolarCool™ And Contro lled Cooling Heat Exchanger Cleaning (Interval - 2 weeks) From the back of the system, remove the sheet meta l service panel…

Preventive Maintenance - XPM
2
6 Revision Date: October 2004
Procedure 2: Inspect and Replace the Exhaust Stack Filter
Interval - 2 weeks
.
All surfaces inside of the oven may be hot. This can include the
exhaust filter chamber and filters. Make sure that the system is
safe to touch before attempting this procedure
Figure 1
Figure 2
1. Lift up on handle to remove rear access panel (this
cover may be on either end depending on oven
configuration)
2. Lift up to remove inner filter cover.
3. Slide stack filters out and replace. Make sure that
the arrows printed on edge of filter are pointing up
in the direction of airflow.
Part # 1481601 Filter 1 x 10 x 20 Polyester
Part # 1481701 Filter 1 x 10 x 20 Sep Pleated
Figure 3
Caution: Filters may contain
hazardous materials. Use
appropriate personal protective
equipment and dispose of in
accordance with local regulations.

Preventive Maintenance - XPM
2
7 Revision Date: October 2004
Procedure 3: PolarCool™ And Controlled Cooling Heat Exchanger Cleaning
(Interval - 2 weeks)
From the back of the system, remove the sheet metal service panels to expose the PolarCool™ or Controlled
Cooling units. Inspect and if necessary vacuum the heat exchanger and coils to maintain adequate airflow.

Preventive Maintenance - XPM
2
8 Revision Date: October 2004
Procedure 4: Clean and Replace Polar Cool Flux Filters.
(Interval - 3 weeks)
.
All surfaces inside of the oven may be hot. This can include
"cool cells". Make sure that the system is safe to touch before
attempting this procedure
Each cooling cell has a removable fin type flux filter that
should be checked, cleaned and replaced periodically. Make
sure the system is cool before attempting this procedure.
Raise the main Hood. Open the hinged housing cover and
remove the heat exchanger fin assembly and properly dispose
of it or clean and reuse by soaking in a flux removing solvent
such as Isopropyl alcohol. Once thoroughly cleaned, replace
the heat exchanger and reassemble.
To remove the Cooling Cell Faceplate, rotate the Retaining
Clips and drop the Faceplate down to soak and/or wipe with
Isopropyl Alcohol. If the face plate is removed.
After releasing the cam locks, remove the "clam shell"
housing from the cell.
The aluminum flux filter is housed within an aluminum
“clam-shell” housing which is seated against the cold plate.
This assembly conducts heat to the cold-plate as well as
filters flux vapors from the oven gas.
The filters require periodic maintenance, but can be
removed cleaned and reused (There is no liquid
connection).
Clean dirty filters with isopropyl alcohol.
Note: Reverse the disassembly process to reinstall the filters
in the oven