Error ID Item Description 060201 Head Up/Down #1 Axis Timing T ask has not been completed unable to continue. (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-start the operation. When the machine…

100%1 / 299
Error ID Item Description
05060b Y2 Axis Servo Error Servo on timeout.
05060c Y2 Axis Servo Error Servo off timeout.
05060d Y2 Axis Servo Error System error.
05060e Y2 Axis Servo Error Invalid command.
05060f Y2 Axis Servo Error Error1 (No Factor)
050610 Y2 Axis Servo Error Error2 (No Factor)
050611 Y2 Axis Servo Error Emergency stop (EXT1) when servo on
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
050701 Y2 Axis Interlock Servo alarm (Interlock board)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
060101 Head Up/Down #1 Axis Origin Encoder origin was not detected.
060102 Head Up/Down #1 Axis Origin Origin sensor (slide) was not detected.
060103 Head Up/Down #1 Axis Origin Origin sensor (slide) and Limit error has been de-
tected.
060104 Head Up/Down #1 Axis Origin Feedback value is indefinite.
060105 Head Up/Down #1 Axis Origin L1 axis is not at origin.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0107-001 2-31 AHB01ETRP
Error ID Item Description
060201 Head Up/Down #1 Axis Timing Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
060301 Head Up/Down #1 Axis Data The driver data was detected outside of the possible
range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
060401 Head Up/Down #1 Axis Limit (+) Limit error has been detected.
060402 Head Up/Down #1 Axis Limit (-) Limit error has been detected.
(Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc.
The sensor may be defective.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
060502 Head Up/Down #1 Axis Servo Alarm Parameter breakdown.
060503 Head Up/Down #1 Axis Servo Alarm Main circuit encoder error.
060504 Head Up/Down #1 Axis Servo Alarm Parameter setting error.
060505 Head Up/Down #1 Axis Servo Alarm Combination error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0107-001 2-32 AHB01ETRP
Error ID Item Description
060510 Head Up/Down #1 Axis Servo Alarm Overcurrent or heat sink overheated.
060530 Head Up/Down #1 Axis Servo Alarm Regenaration error detected.
060532 Head Up/Down #1 Axis Servo Alarm Regenarative overload.
060540 Head Up/Down #1 Axis Servo Alarm Overvoltage.
060541 Head Up/Down #1 Axis Servo Alarm Undervoltage.
060551 Head Up/Down #1 Axis Servo Alarm Overspeed.
060571 Head Up/Down #1 Axis Servo Alarm Overload: High load.
060572 Head Up/Down #1 Axis Servo Alarm Overload: Low load.
060573 Head Up/Down #1 Axis Servo Alarm Dynamic brake overload.
060574 Head Up/Down #1 Axis Servo Alarm Overload of surge current limit resistor.
06057a Head Up/Down #1 Axis Servo Alarm Heat sink overheated.
060581 Head Up/Down #1 Axis Servo Alarm Encoder backup error.
060582 Head Up/Down #1 Axis Servo Alarm Encoder checksum error.
060583 Head Up/Down #1 Axis Servo Alarm Absolute encoder battery error.
060584 Head Up/Down #1 Axis Servo Alarm Encoder data error.
060585 Head Up/Down #1 Axis Servo Alarm Encoder overspeed.
060586 Head Up/Down #1 Axis Servo Alarm Encoder overheated.
060591 Head Up/Down #1 Axis Servo Alarm Overload warning.
060592 Head Up/Down #1 Axis Servo Alarm Regenerative overload warning.
060594 Head Up/Down #1 Axis Servo Alarm Setting warning.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0107-001 2-33 AHB01ETRP