4OM-1075-002 - 第144页
Error ID Item Description 0b0601 Nozzle Change #2 Interlock Step out was detected. 0b0602 Nozzle Change #2 Interlock 0b0603 Nozzle Change #2 Interlock 0b0604 Nozzle Change #2 Interlock 0b0605 Nozzle Change #2 Interlock (…

Error ID Item Description
0b0201 Nozzle Change #2 Axis Data
0b0202 Nozzle Change #2 Axis Data
0b0203 Nozzle Change #2 Axis Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0301 Nozzle Change #2 Communication
0b0302 Nozzle Change #2 Communication
0b0303 Nozzle Change #2 Communication
0b0304 Nozzle Change #2 Communication
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0401 Nozzle Change #2 Change Nozzle Change failed.
0b0402 Nozzle Change #2 Change
(Cause 1) Self-Diagnostics Error Message
(Cause 2) It can be assumed that the nozzle change cam in the head section might be worn
out.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Refer to "1.4.1 Replacement of Nozzle Change Cam" in "Section 1" and replace
the cam with a new one.
3.3 Error IDs and Remedial Procedures
0206-003 2-53 AHB01ETRP

Error ID Item Description
0b0601 Nozzle Change #2 Interlock Step out was detected.
0b0602 Nozzle Change #2 Interlock
0b0603 Nozzle Change #2 Interlock
0b0604 Nozzle Change #2 Interlock
0b0605 Nozzle Change #2 Interlock
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0b0701 Nozzle Change #2 Operation Error Nozzle Change result error.
0b0702 Nozzle Change #2 Operation Error Nozzle Change result error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0c0101 Backup Up/Down Axis Origin Encoder origin was not detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-002 2-54 AHB01ETRP

Error ID Item Description
0c0102 Backup Up/Down Axis Origin Origin sensor (slide) was not detected.
0c0103 Backup Up/Down Axis Origin Origin sensor (slide) and Limit error has been de-
tected.
(Cause 1) The backup U/D axis might have overrun due to a defective sensor, a broken cable,
generation of noises, or overcurrent.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0c0104 Backup Up/Down Axis Origin Feedback value is indefinite.
0c0105 Backup Up/Down Axis Origin BPC axis is not at origin.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0308-001 2-54-1 AHB01ETRP